Test Functions - Abus Terxon SX AZ4000 Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

15.4

Test functions

090 Event memory
UK
The alarm centre stores the last 250 events. Each event is
stored with date and time. The event memory can be
viewed via the program menu.
1. On the control unit, enter:
2. The LCD display shows the latest events first.
3. You can page forwards and backwards in the
event memory. Press key 1 to page forwards and
key 3 to page backwards.
4. Press
date.
5. Press
6. The event memory cannot be deleted by the
programmer or the user.
Entries in the event memory and their meaning:
Entry
MAINS Fail
MAINS Fail
OK
Alarm Abort
AUX DC Fail
AUX DC Fail
OK
Bad
Checksum
Batt Load Fail Failure of battery charger or battery fuse
Batt Load Fail
OK
Burg Zone nn Zone nn has triggered a burglar alarm
Burg Zone nn
OK
Defaults
Loaded
090
to switch between the event and the
to exit the event memory.
Meaning
Failure of 230V AC power supply
230V AC power supply restored
Alarm aborted manually by user
12V DC power supply failed or AUX fuse
defect
12V DC power supply restored
Error in alarm centre memory
defect
Battery charger restored
Zone nn OK
Factory settings restored
EEPROM Fail Memory error in the alarm centre
Fire Zone nn
Zone nn has triggered a fire alarm
Fire Zone nn
Zone nn reset
OK
Fire OK
Fire alarm reset
Excess Keys
A user has tried too often to enter code
in the control unit
Keyboard
Control unit nn failed
Missing
Keyboard
Control unit nn reconnected
Restore
Keyboard
Control unit has triggered a tamper
Tamper
alarm
Keyboard
Control unit nn tamper reset
Restore
Fire Zone
Fire alarm triggered at control unit nn
Alarm
Medical Zone
Medical emergency alarm triggered at
Alarm
control unit nn
Key Sw Set #
Alarm centre activated via key switch of
zone nn
Entry
Meaning
Key Sw
Alarm centre deactivated via key switch
Unset #
of zone nn
Key Box Cls
Zone nn with key box property closed
Z#
Key Box Opn
Zone nn with key box property opened
Z#
Lid Tamper
The lid contact of the alarm centre was
triggered
Lid Tamper
The lid contact of the alarm centre is
Restore
closed again
Batt missing
Battery supply interrupted (cable not
plugged in)
Batt Flt
Battery supply restored (cable
Restore
connected)
PA K -- Alarm BDT nn has triggered a panic alarm
PA Z -- Alarm Zone nn has triggered a panic alarm
PA Z -- Rstr
Panic alarm of zone nn reset
Set Fail Zone
The alarm centre could not be activated
--
since ZN nn was triggered
Fire Z –
Zone nn has triggered a fire alarm
62

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents