Alarm
Fire Z -- Rstr
Zone nn fire alarm reset
Soak Fail Z --
Zone nn sensor test failed
Bell Tamper
Siren tamper alarm reset
Rst
Bell Tamper
Siren tamper alarm triggered
System
System automatically rearmed
Rearmed
System
System supplied with power and started
Startup
Tamper Z --
Zone nn has triggered a panic alarm
Tamper Z --
Zone nn panic alarm reset
Restore
Tech Z --
Zone nn has triggered a technical alarm
Alarm
Tech Z --
Zone nn alarm reset
Restore
Tel Line Fault Error in transmission (not for Terxon SX)
Tel Line
Transmission error reset
Restrore
User--
User nn has changed the user code of
Change User-
user nn
-
User-- Delete
User nn has deleted the user code of
User--
user nn
U -- Off-Site
User nn has exited the program menu
U -- On-Site
User nn has entered the program menu
User--
User nn has reset the alarm centre
System Reset
User-- # Set
User nn has activated the alarm centre
(area #)
User-- #
User nn has deactivated the alarm
Unset
centre (area #)
User--
User nn has changed the time and date
Time/Date
User Zone #
User nn has removed ZN nn from
Omit
monitoring
User Zone #
User nn has returned ZN nn to
Unomit
monitoring
Global
Only for zone property NC + tamper:
Tamper
Tamper line (COM A/T) triggered
Global T.
Tamper line (COM A/T) reset
Restore
091 Test output 1
The alarm centre activates output 1 on the centre's PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press:
092 Test output 2
The alarm centre activates output 2 on the centre's PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press:
093 Test output 3
The alarm centre activates output 3 on the centre's PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press:
094 Test loudspeaker output
The alarm centre activates the output for the optional
loudspeaker on the PCB until it is terminated manually. To
start the test, you must open the program menu. Proceed
as follows:
1. On the control unit, enter:
2. To end the test, press:
095 Test control unit buzzer
The alarm centre activates the control unit buzzer until it is
terminated manually. To start the test, you must open the
program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press:
63
091
.
092
.
093
.
094
.
095
.
UK