After entering the zone name, enter the zone property.
Zone properties are explained on pages 19 and 20 of
these instructions. Enter the zone property as follows:
1. Enter the zone property via the keypad as follows:
UK
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
2. After entering the zone property, enter the area
for which this zone is to be monitored. For an
explanation of areas, see page 20 of these
instrauctinos. Enter the area via the keypad as
follows:
A
B
C
d
,
NU – Not Used
PA – Panic
Fr – Fire
NA – Immediate
24 – 24 hours
FE – Entry/exit
Er – Entry to follow
SA – Shock sensor
Tc – Technical zone
KB – Keybox
SD – Fire alarm
KM – Key switch pulse
KF – Key switch stable
AM – not used
FB – Forbikobler
This zone is monitored if area A is
active.
a
The LCD display shows:
This zone is monitored if area B is
active.
b
The LCD display shows:
This zone is monitored if area C is
active.
c
The LCD display shows:
This zone is monitored if area D is
active.
d
The LCD display shows:
3. Apart from the zone property and the area in
which the zone is to be monitored, there are also
zone attributes. Via the keypad,
enter the zone attributes as follows:
C – door chime
The alarm centre always generates a
tone on the control unit and the
loudspeaker if a zone with this zone
X1
attribute is triggered. This applies only if
the burglar alarm centre is deactivated.
This zone is available for zones with the
properties "immediate", "entry/exit",
"entry", "follow" and "shock sensor".
S – Sensor test
Zones with this zone attribute are in a
test function. Use this test function if
you think a sensor may trigger a false
alarm. This zone starts a 14-day test. If
this zone triggers an alarm within 14
days, no general alarm state is
declared. The sensor is removed from
X2
monitoring and a message is displayed.
If the zone triggers no alarm within 14
days, the zone test ends, the zone
attribute is deleted and the zone works
normally again.
This zone is available for zones with the
properties "immediate", "entry to follow",
"technical" and "shock sensor".
D – Zone link
Zones with this zone attribute first
trigger an alarm when a further zone
triggers an alarm with 5 minutes or if a
zone is open for at least 10 seconds
X3
(e.g.: magnetic contacts). This function
reduces false alarms from individual
sensors to a minimum, but a burglary
may be detected too late or not at all.
This zone is available for zones with the
properties "immediate", "entry to follow".
O – Lock zone
Zones with this zone attribute can be
X4
locked manually by the user and
removed from monitoring.
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents