Diagnostic Error Code
089-198-XXXMicroprocessor test aborted
089-199-XXXMicroprocessor test failed, cause
unknown
170-000-XXXVoltage Sensor(s) Test Passed
170-0XX-XXXVoltage Sensor(s) failure
170-195-XXXVoltage Sensor(s) Test aborted
by user
170-196-XXXVoltage Sensor(s) test halt, error
threshold exceeded
170-197-XXXVoltage Sensor(s) test warning
170-198-XXXVoltage Sensor(s) test aborted
170-199-XXXVoltage Sensor(s) test failed,
cause unknown
170-250-XXX 170-251-XXXVoltage Sensor(s)
Voltage limit error
170-254-XXXVoltage Sensor(s) Voltage
Regulator Module error
175-000-XXXThermal Sensor(s) Test Passed
175-0XX-XXXThermal Sensor(s) failure
175-195-XXXThermal Sensor(s) Test aborted
by user
175-196-XXXThermal Sensor(s) test halt,
error threshold exceeded
FRU/Action
1. Flash the system and re-test
2. Go to the "Undetermined problems"
section
1. If a component is called out, make sure
it is connected and/or enabled
2. Go to the "Undetermined problems"
section
3. Flash the system and re-test
4. Replace component under function test
1. No action
1. Flash system
2. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the "Undetermined problems"
section
1. Go to the "Undetermined problems"
section
2. Flash the system and re-test
3. Replace component under function test
1. Power supply
2. System board
1. Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
1. No action
1. Flash system
2. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 7. Symptom-to-FRU index