Managing cables for the Ethernet Routing Switch 8000 Series chassis 95
Managing cables: 8010, 8006, 8003 chassis
Route the cable to the termination panel, loosely fastening the cable
with Velcro straps or sheet fiber along the path.
Fasten the connector onto the termination panel end of the cable.
Use the instructions supplied with the connector. If you are using
cables manufactured by Nortel, the connectors are already fastened
to predetermined lengths of cable.
Label the unconnected end of the cable with the node identifier (from
site records) and the shelf, cage, slot, and port number.
When all the transmitting cables from the same module are
connected to the termination panel, use Velcro straps or sheet fiber
wrapped around the cables to manage them.
Using scissors, cut a section of the sheet fiber that is wide enough to
wrap around the cables.
Using scissors, round the corners of the sheet fiber section.
Loosely wrap the sheet fiber and secure it using lacing cord or tie
wraps
("Wrapping cables with sheet fiber and securing with lacing
cord" (page
96)).
Nortel Metro Ethernet Routing Switch 8600
Installation — Modules
NN46220-306 02.02 Standard
4.2 7 July 2008