Nortel 8004DC Installation Manual
Nortel 8004DC Installation Manual

Nortel 8004DC Installation Manual

Ethernet routing switch 8600 installation - dc power supply
Hide thumbs Also See for 8004DC:
Table of Contents

Advertisement

Quick Links

Nortel Ethernet Routing Switch 8600
Installation — DC Power Supply
Release: 5.0
Document Revision: 02.02
www.nortel.com
NN46205-307
313070-F Rev 02
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8004DC and is the answer not in the manual?

Questions and answers

Summary of Contents for Nortel 8004DC

  • Page 1 Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply Release: 5.0 Document Revision: 02.02 www.nortel.com NN46205-307 313070-F Rev 02...
  • Page 2 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.
  • Page 3: Table Of Contents

    Navigation 25 Ethernet Routing Switch 8600 DC power supplies 25 8004DC power supply 26 Minimum number of 8004DC power supplies to install 26 Redundant power configuration 27 8005DC power supply 27 Minimum number of 8005DC power supplies to install 28...
  • Page 4 Electric shock danger statement 61 Electric shock danger statement 62 Technical specifications Technical specifications navigation 65 Model 8004DC power supply 65 DC input power specifications 65 DC output power specifications 66 Model 8005DC power supply 67 DC input power specifications 67...
  • Page 5: Regulatory Information And Safety Precautions

    Read the information in this section to learn about regulatory conformities and compliances. International Regulatory Statements of Conformity This is to certify that the Nortel 8000 Series chassis and components installed within the chassis were evaluated to the international regulatory standards for electromagnetic compliance (EMC) and safety and were...
  • Page 6 EN 55 024 Statement This is to certify that the Nortel 8000 Series chassis is shielded against the susceptibility to radio interference in accordance with the application of Council Directive 2004/108/EC. Conformity is declared by the application of EN 55 024 (CISPR 24).
  • Page 7 Class A requirements of the Republic of Korea Ministry of Information and Communications (MIC). This device may not be sold for use in a non-business application. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 8 CE Marking Statement (Europe only) EN 60 950 Statement This is to certify that the Nortel 8000 Series chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance.
  • Page 9 Exportador: Nortel Networks, Inc. 4655 Great America Parkway Santa Clara, CA 95054 USA Importador: Nortel Networks de México, S.A. de C.V. Avenida Insurgentes Sur #1605 Piso 30, Oficina Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright ©...
  • Page 10 200-240 VCA, 50-60 Hz, 9.3 A max por fuente de poder Model 8004DC: -48 VCD, 29 A Model 8005DC: -48 VCD, 42 A Denan Statement (Japan/Nippon only) Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 11 This section describes the different precautionary notices used in this document. This section also contains precautionary notices that you must read for safe operation of the Nortel Ethernet Routing Switch 8600. Notices Notice paragraphs alert you about issues that require your attention.
  • Page 12 12 Regulatory Information and Safety Precautions CAUTION ATTENZIONE ESD Le indicazioni ESD forniscono informazioni per evitare scariche di elettricità statica e i danni correlati per i prodotti Nortel. Caution Notice CAUTION Caution notices provide information about how to avoid possible service disruption or damage to Nortel products.
  • Page 13 Nortel. WARNING AVISO Os avisos oferecem informações sobre como evitar ferimentos ao trabalhar com os produtos da Nortel. WARNING AVVISO Le indicazioni di avviso forniscono informazioni per evitare danni alle persone durante l’utilizzo dei prodotti Nortel.
  • Page 14 PERIGO Avisos de perigo oferecem informações sobre como evitar uma situação ou condição que possa causar graves ferimentos ou morte. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 15 PERICOLO Le indicazioni di pericolo forniscono informazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle persone o il decesso. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 16 16 Regulatory Information and Safety Precautions Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 17: Software License

    30 days of purchase to obtain a credit for the full purchase price. "Software" is owned or licensed by Nortel Networks, its parent or one of its subsidiaries or affiliates, and is copyrighted and licensed, not sold. Software consists of machine-readable instructions, its components, data, audio-visual content (such as images, text, recordings or pictures) and related licensed materials including all whole or partial copies.
  • Page 18 Upon termination or breach of the license by Customer or in the event designated hardware or CFE is no longer in use, Customer will promptly return the Software to Nortel Networks or certify its destruction. Nortel Networks may audit by remote polling or other reasonable means to determine Customer’s Software activation or usage levels.
  • Page 19 Customer fails to comply with the terms and conditions of this license. In either event, upon termination, Customer must either return the Software to Nortel Networks or certify its destruction. Customer is responsible for payment of any taxes, including personal property taxes, resulting from Customer’s use of the Software.
  • Page 20 20 Software license Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 21: New In This Release

    New in this Release The following sections detail what’s new in Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply (NN46205-307) for Release 5.0: • “Features” (page 21) • “Other changes” (page 21) Features There are no new features included in this NTP.
  • Page 22 22 New in this Release Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 23: Introduction

    Ensure the switch is properly grounded before powering on the unit. For the minimum Ethernet Routing Switch 8600 software version required to support the hardware, see Nortel Ethernet Routing Switch 8600 Administration (NN46205-600) . Task and estimated time The following table lists the estimated time to install a DC power supply in the Ethernet Routing Switch 8600 chassis.
  • Page 24 “DC power supply fundamentals” (page 25) • “DC power supply installation” (page 31) • “Translations of safety messages” (page 55) • “Technical specifications” (page 65) Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 25: Dc Power Supply Fundamentals

    This section describes the Ethernet Routing Switch 8600 DC power supplies. The 8006, 8010, and 8010co chassis each have three power supply bays in which you can install either the 8004DC or the 8005DC power supply. CAUTION The 8004DC and 8005DC power supplies have different power ratings.
  • Page 26: 8004Dc Power Supply

    8004DC or 8005DC power supply with these modules. 8004DC power supply Each 8004DC power supply provides 850 watts (W) of power to the switch. Figure 1 "8004DC power supply" (page 26) shows the 8004DC power supply used in the 8006, 8010, and 8010co chassis.
  • Page 27: Redundant Power Configuration

    The chassis continues to supply the same module output power with the remaining power supplies. A trap and syslog message indicates that the configuration is non-redundant. Nortel recommends that you operate the Ethernet Routing Switch 8600 system in a redundant configuration at all times to ensure maximum network performance.
  • Page 28: Minimum Number Of 8005Dc Power Supplies To Install

    The chassis continues to supply the same module output power with the remaining power supplies. A trap and syslog message indicates that the configuration is non-redundant. Nortel recommends that you operate the Ethernet Routing Switch 8600 system in a redundant configuration at all times to ensure maximum network performance.
  • Page 29 For information on configuring power management using the CLI, NNCLI and Device Manager, see Nortel Ethernet Routing Switch 8600 Administration (NN46205-605) . To display the total power the switch uses and the total power the power supplies provide, see Nortel Ethernet Routing Switch 8600 Administration (NN46205-605) .
  • Page 30 30 DC power supply fundamentals Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 31: Dc Power Supply Installation

    Ethernet Routing Switch 8600 software version required to support the hardware. ATTENTION Nortel recommends that you install each power supply on its own dedicated branch circuit to ensure that a fault on another branch circuit does not cascade to other branch circuits.
  • Page 32: Dc Power Supply Installation Procedures

    DC power supply in the Ethernet Routing Switch 8600. To link to any tasks, go to “DC power supply installation navigation” (page 34). Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 33 DC power supply installation procedures 33 Figure 3 Installation — DC Power Supply task flow Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 34: Verify The Dc Power Supply Shipping Accessories

    Table 2 "DC power supply shipping accessories: 8004DC" (page as a checklist to verify the contents of the 8004DC shipping container. Table 2 DC power supply shipping accessories: 8004DC...
  • Page 35: Determining The Minimum Number Of Dc Power Supplies

    Determining the minimum number of DC power supplies Use the following procedure to determine the minimum number of power supplies to install for the Ethernet Routing Switch 8600 system: For more information, see Nortel Ethernet Routing Switch 8600 Installation — Chassis (NN46205-303) . Procedure steps...
  • Page 36: Preparing Cables For Installation

    Prepare the cables for installation of the power supply of the Ethernet Routing Switch 8600. Nortel does not supply the cables for connecting the DC power supply to the DC input power source. Select cables that comply with the electrical code of the country where you use the DC power supply.
  • Page 37 If necessary, use a heat gun to shrink the tubing around the cable. --End-- Job aid: Cable stripping requirements The illustrations in this section provide details about cable stripping requirements for 8004DC and 8005DC power supplies. Figure 4 Cable stripping requirements for 8004DC Figure 5 Cable stripping requirements for 8005DC Nortel Ethernet Routing Switch 8600 Installation —...
  • Page 38: Removing The Bottom Bezel 312096-A Of The 8010Co Chassis

    Step Action Use a Phillips screwdriver to loosen the two captive screws that secure the bezel to the chassis (see the following figure). Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 39 Removing the bottom bezel 312096-A of the 8010co chassis 39 Pull the top of the bezel forward and lift the bezel from the two tabs on the bottom of the chassis. --End-- Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 40: Removing The Power Filler Panel

    Use the following procedure to remove the power filler panel. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 41 Ethernet Routing Switch 8600 with a power supply removed. --End-- Job aid: Power filler panel removal Figure 7 Removing a power filler panel: 8010co chassis Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 42: Installing The Dc Power Supply

    312096-A installed, you must remove the bottom front bezel. For instructions, see “Removing the bottom bezel 312096-A of the 8010co chassis” (page 38). Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 43 “Job aid: Inserting the DC power supply” (page 47). ATTENTION If you install the 8004DC power supply in a 8010co chassis and you have the optional breaker interface panel (BIP), see Nortel Ethernet Routing Switch 8600 Installation — Breaker Interface Panel (NN46205-313) .
  • Page 44 49). Use the washers in the following order: a flat washer b crimp lug c lock washer d Hex nut Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 45 Attach the earth ground cable to the system or rack ground for your DC input power source. Use a Phillips screwdriver to replace the plastic safety cover on the power supply. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 46 Turn the DC input power source on or reset the power source circuit breaker to provide power to the power supply. Turn the power supply switch to the on position. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright ©...
  • Page 47 ATTENTION Due to the N+1 power sharing architecture, if your chassis contains two or three non-redundant power supplies, Nortel recommends that you turn on the power supplies simultaneously. If you wait longer to turn on the supplies, the power supplies shut off within 7 seconds. To correct this condition, turn off the power supplies for 2 minutes, and then simultaneously turn on the power supplies again.
  • Page 48 48 DC power supply installation Job aid: DC power supply input and ground stud location Figure 11 8004DC power supply input and ground stud location Figure 12 8005DC power supply input and ground stud location Nortel Ethernet Routing Switch 8600 Installation —...
  • Page 49 Figure 13 Attaching the earth ground lead to the ground stud (8004) Figure 14 Attaching the earth ground lead to the ground studs (8005) Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 50: Replacing The 8010Co Chassis Bottom Bezel Model 312096-A

    312096-A, or if you have difficulty installing the bezel over the 8005DC power supplies, you can order modified bezel model 321325-A (Order Code DS1411027). Step Action Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 51 Push the sides of the bezel into place. Using a Phillips screwdriver, tighten the two screws to secure the bezel to the chassis. --End-- Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 52: Replacing The 8010Co Chassis Bottom Bezel Model 321325-A

    See figure below. Place the top of the bezel against the chassis. Align the captive screws with the holes on the front of the chassis. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 53: Nn46205-307

    Replacing the 8010co chassis bottom bezel model 321325-A 53 Using a Phillips screwdriver, tighten the two screws to secure the bezel to the chassis. --End-- Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 54 54 DC power supply installation Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 55: Translations Of Safety Messages

    Este es un producto clase A. El uso de este equipo en áreas residenciales puede causar interferencias nocivas, en cuyo caso, se requerirá que los usuarios tomen cualquier medida necesaria para corregir la interferencia por cuenta propia. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 56: Electrostatic Discharge Caution Statement

    Entladung zu verhindern, tragen Sie bei der Instandhaltung dieses Produkts immer ein antistatisches Band am Handgelenk, welches mit einer ESD-Buchse verbunden ist. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 57: Power Filler Panel Caution Statement

    ACHTUNG Bewahren Sie die Aussparungsabdeckung für den Fall auf, dass Sie Ethernet Routing Switch 8600 verwenden müssen, wenn ein Netzteil entfernt ist.. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 58: Empty Power Supply Bay Caution Statement

    Ethernet Routing Switch 8600 lorsque la baie d’alimentation est vide. Ne retirez pas une alimentation, même défectueuse, si vous ne disposez pas d’un panneau de remplissage à installer à sa place. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 59 Se si sostituisce un alimentatore guasto e non si dispone di un pannello di riempimento, lasciare installato l’alimentatore guasto finché non sarà disponibile un alimentatore per la sostituzione. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 60: Usage Of Connection Cable Caution Statement

    Controle que el cable de conexión que utilice con la fuente de alimentación de CC sea el adecuado. Para determinar qué cables debe utilizar, evalúe el calibre, la inflamabilidad y la funcionalidad mecánica. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 61: Electric Shock Danger Statement

    DANGER GEFAHR Verletzungsrisiko durch Stromschlag Es besteht ein Sicherheitsrisiko, wenn die Anschlussstücke nicht ordnungsgemäß auf die Kabel geklemmt werden. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 62: Electric Shock Danger Statement

    électriques. Utilisez uniquement des cordons d’alimentation possédant un conducteur de terre. Assurez-vous que le commutateur est correctement relié à la terre avant de mettre l’unité sous tension. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 63 Utilizzare esclusivamente cavi di alimentazione dotati di un percorso per il collegamento a terra. Prima di attivare l’alimentazione dell’unità, accertarsi che l’interruttore sia adeguatamente collegato alla messa a terra. Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008...
  • Page 64 64 Translations of safety messages Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 65: Technical Specifications

    8010co BIP. Electrical code compliance requires this limitation because of the difference between the 8010co BIP output circuit protection rating of 30 A and the 8004DC power supply input current rating of 29 A at –48 VDC nominal operating condition.
  • Page 66: Dc Output Power Specifications

    8010co BIP. Electrical code compliance requires this limitation because of the difference between the 8010co BIP output circuit protection rating of 30 A and the 8004DC power supply input current rating of 29 A at –48 VDC nominal operating condition.
  • Page 67: Model 8005Dc Power Supply

    12 V @ 72 A Fans 12 VDC @ 7.5 A/ 24 A peak 108 803 hr MTBF (Bellcore TR–332 standard) Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 68 68 Technical specifications Nortel Ethernet Routing Switch 8600 Installation — DC Power Supply NN46205-307 02.02 19 December 2008 Copyright © 2008 Nortel Networks...
  • Page 70: Installation - Dc Power Supply

    While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.

This manual is also suitable for:

8005dc

Table of Contents