Installation/wall mounting

Note: for wall installation,
the enclosed inside corner
bracket can also be used.
The cables can therefore be
passed conveniently from
above behind the fixture and
through the opening for sur-
face-mounted wiring.
Surface-mounted
wiring with wall bracket
14
The installation site should
be at least 50 cm from a
light, since the latter's heat
radiation could result in
false triggering of the sen-
sor. In order to achieve the
given reach of 5/12 m, the
installation height should be
approx. 2 m.
Installation steps:
1. Remove decorative
cover
, 2. Release catch
and fold up lower half of
housing, 3. Mark drilling
holes, 4. Drill the holes and
insert plugs (6 mm dia.),
Power supply lead
5. Prepare wall according
flush fitted
to needs for flush or sur-
face mounted wiring.
6. Wire up the supply and
service leads and connect.
Use sealing plugs for sur-
face mounted wiring.
a) Connection of the
supply lead
Power supply lead
The supply lead consists
surface mounted
of a 2-3 phase cable:
L
= phase conductor
N = neutral conductor
PE = protective-earth
conductor
If in doubt, the cable must
be identified with a voltage
Supply lead
tester. Switch off the cur-
Service lead
rent again. The phase (L)
and neutral (N) conductors
are to be connected
according to the terminal
assignment. The protective-
earth conductor is to be
clamped to the earth con-
tact ( ).
A mains switch for ON and
OFF switching can of cour-
se be installed in the mains
lead.
Installation/corner wall mounting
b) Connection of the
The earth conductor is to
service lead
be connected to the earth
The service lead (e.g. light)
contact. 7. Screw on the
likewise consists of a 2-3
housing and close,
phase cable. The phase
8. Apply lens (reach option-
conductor of the consumer
ally max. 5 m or 12 m),
is connected to the termi-
refer to Reach setting
nal marked L'. The neutral
chapter, 9. Perform time
conductor is clamped to
and twilight
the terminal marked N
(refer to Functions chapter),
together with the supply
10. Apply decorative cover
lead neutral conductor.
and safeguard against
Functions
After the mains connection
on. Two setting options are
has been made, the hous-
concealed behind the de-
ing has been closed and
corative cover
the lens has been applied,
the unit can be switched
Switch-off delay
(time setting)
The desired period of op-
eration of the light fixture
can be adjusted continu-
ously from approx. 10 sec.
to a max. of 15 min. When
the adjustment screw is at
the left stop position, this
means the shortest time of
10 sec.–15 min.
10 Sek.-15 Min.
Twilight setting
(response threshold)
The desired sensor res-
ponse threshold can be
adjusted continuously from
approx. 2 lux to 2000 lux.
When the adjustment screw
is at the left stop position,
this means twilight opera-
tion of approx. 2000 lux.
2 - 2000 Lux
2–2000 lux
unauthorised removal with
safety screw
.
Important: reversing the
connections can result in
damage to the fixture.
settings
The sensor can be mounted
conveniently on inside and
outside corners using the
enclosed corner wall mounts.
Use the corner wall mount
as a drilling template when
drilling the holes. In this
manner, the drill hole will be
positioned at the correct
angle and the corner wall
mount can be installed easily.
Important: perform time
and twilight setting only
.
with the lens installed.
approx. 10 sec. When the
adjustment screw is at the
right stop position, this
means the longest time of
approx. 15 min. It is recom-
mended to select the shor-
test time when setting the
detection zone and for the
functional test.
When the adjustment screw
is at the right stop position,
this means twilight opera-
tion of approx. 2 lux. The
adjustment screw must be
at the left stop position
when setting the detection
zone and for the functional
test in daylight.
15