Electrical Connection; Installation - STEINEL professional Series Manual

Hide thumbs Also See for professional Series:
Table of Contents

Advertisement

Available languages

Available languages

Technical specifications
– HF 360-2 dimensions (H × W × D):
Concealed installation (UP):
Surface-mounted installation (AP):
– Hallway dimensions (H × W × D):
Concealed installation (UP):
Surface-mounted installation (AP):
– Mounting height:
– Angle of coverage:
– HF 360-2 reach:
– Hallway reach:
– Sensor values:
Relative humidity: 0 – 100 %
– Temperature range:
– IP rating:
– Bluetooth frequency:
– Bluetooth transmission power:
– HF 360-2 / Hallway frequency:
– Transmission power:
Power consumption via DALI
(12 – 22.5 V DC, no SELV):
– Max. current consumption in accord-
ance with IEC 62386-101::
HF 360-2: 84 mA / 42 devices
Hallway: 84 mA / 42 devices
– Typical current consumption at an input
voltage of 16 V in regular operation *:
HF 360-2: 21 mA / 11 devices
Hallway: 25 mA / 13 devices
– Max. current consumption at an input
voltage of 10 V in regular operation *:
HF 360-2: 38 mA / 19 devices
Hallway: 46 mA / 23 devices
* These values will not be exceeded in
regular operation and can be used as the
basis for planning.
103 × 103 × 61 mm
123 × 123 × 57 mm
103 × 103 × 66.5 mm
123 × 123 × 62 mm
2 – 4 m
Ø 12 m
25 × 3 m
Light measurement,
Temperature: 0 – 40 °C,
0 °C to +40 °C
2.4 – 2.48 GHz
5 dBm / 3 mW
5,8 GHz
3 dBm / 2 mW

4. Electrical connection

DA+ = Connection to the DALI BUS
(brown)
DA- = Connection to the DALI BUS
(blue)
Surface-mounted connection (Fig. 4.1)
Concealed connection (Fig. 4.2)

5. Installation

360°
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting
location, taking the reach and
motion detection into consideration.
(Fig. 3.13, Fig. 3.14)
• Aim sensor in appropriate direction.
IP20
Hallway DALI-2 IPD. (Fig. 5.1)
Mounting procedure
• Switch off power supply. (Fig. 4.1,
Fig. 4.2)
Concealed mounting
• Make connection. (Fig. 5.2, 4.2)
• Firmly screw load module into mount-
ing box. (Fig. 5.3)
• Fit magnetic sensor module on frame.
(Fig. 5.4)
• Switch ON power supply. (Fig. 5.4)
• Make settings.
 "6. Function and settings"
Surface mounting
• Mark drill holes and drill. (Fig. 5.5)
• Screw load module into place.
(Fig. 5.6)
• Make connection. (Fig. 5.7, Fig. 4.1)
• Break out the mounting tab. (Fig. 5.8)
• Fit surface-mounting adapter. (Fig. 5.9)
• Fit magnetic sensor module. (Fig 5.10)
• Switch ON power supply. (Fig. 5.10)
• Make settings.
 "6. Function and settings"