Installation instructions

About these instructions

Instructions to take action are shown as
follows:
► Instruction to take action
In the safety advice, the warning symbol
and signal word indicate the severity of
danger:
!

Signal word

Type and source of danger
Measures to avoid dangers
► Read these installation instructions
before installing the product.

Further information

You will find further information at:
www.steinel.de
Proper use
The IS 2360-3 ECO outdoor sensor can
be used as an indoor and outdoor mo-
tion detector. Working with three pyro
sensors, it detects heat radiated from
moving objects and switches ON lights
that are connected to it. The product is
only suitable for installing on ceilings
and may only be operated in line with
the technical specifications.
All connecting work at the electrical
connections may only be carried out by
a qualified electrician and in compliance
with national regulations.
Product parts (Fig. A)
Holder for ceiling mounting
1 Rating plate
2 Mounting holes
3 Connections
N neutral conductor
Arrow Power supply lead for light
L  Mains power supply
4 Cable entries
5 Contact point for protective-earth
conductor
Sensor housing
6 two control dials:
Response threshold and
stay-ON time
7 Housing attachment
with screw
8 Shrouds
9 Cover ring
10 Pilot holes for drainage
11 Fixing material
Checking package contents and
product
► Check to make sure that the product
is complete and undamaged.
► Do not open the housing if it is dam-
aged, and do not repair the product
yourself.
► Carefully pack the damaged product
and send it with a brief description of
the fault and proof of purchase (in-
voice) to a Steinel service station.
- 18 -
Preparing to install (Fig. B)
Defining point of installation
► Define the mounting position as
follows:
• Minimum distance of 50 cm from
lights and other sources of heat
• Unobstructed line of vision between
the sensor and detection zone (obsta-
cles include walls, glass panels,
trees)
• Mounting height of 2.50 m to 2.80 m
for optimum reach
Planning usage
!
Caution
Risk of short-circuiting from
overloading
When planning the number of lights to
connect, always be sure not to exceed
the maximum switching capacity, e.g.
2000 watts for light bulbs, see section
"Technical specifications".
Checking ambient conditions
If you are using the product in a very
damp or humid environment:
► Drill drainage holes in the pilot
holes (10) using a 5 mm drill bit
Installing (Fig. C)
D
Danger
Danger to life from touching live
cables!
Disconnect cables from the power
supply!
► Detach the cover ring (9) and the
shrouds (8).
► Undo the housing attachment screw
(7) and push it out of the holder.
► Drill holes at the intended mounting
position.
► Attach the holder with the fixing ma-
terial (11).
Connecting IS 2360-3 ECO (Fig. D)
D
Danger
Danger to life from electric shock!
All work at the connections may only be
performed by a qualified electrician.
► Using a voltage tester, check to make
sure that all cables are disconnected
from the power supply.
► Thread the cables through the cable
entries (4).
► Attach the PE conductor (yellow and
green conductor) at the contact point
(5).
► Connect the neutral conductor (blue
or grey conductor) to the neutral con-
ductor terminal N.
► Connect the live (black) conductor to
the mains power supply terminal L.
Connecting power supply lead for
lights
► Connect the power supply lead for
light (brown) to the arrow terminal.
Note
Protection class IP54 is only ensured if
the sealing plugs are fitted.
- 19 -