Table 4
MCG 3100 configuration parameter fields
Field
Gateway Address
Backup Gateway SIP
Listening Address
Gateway SIP Listening
Address
Primary ECS Address
Secondary ECS Address
Group Call Server Address

Nortel Mobile Communication Gateway 3100 Installation and Upgrades

Copyright © 2007, 2008 Nortel Networks
.
Action
Log on to the MCG 3100 Web Console using the Administrator
username and password, as described in
on to the MCG 3100 Web Console" (page
Click Gateway.
Click Configuration for the Gateway you want to modify.
Click Unlock.
The configuration parameters unlock and can be modified.
Modify the configuration parameters as required.
For a description of the parameter fields, see
"MCG 3100 configuration parameter fields" (page
Click Save to save the modified parameters.
Click OK to restart the server.
Description
The IP address that the local MCG 3100 uses for HTTP traffic.
The IP address and port of the second MCG 3100 in a redundant
pair.
Syntax: [IP]:[port]
Example: 192.167.130.76:5060
The host name or IP address where the SIP gateway receives
inbound SIP requests over UDP.
Syntax: [IP]:[port]
Example: 192.167.130.75:5060
The IP address and port of the primary Enterprise Communication
Server. For CS 1000, this is the primary SIP Proxy Server (SPS).
Syntax: [IP]:[port]
Example: 192.167.101.2:5060
The IP address and port of the secondary Enterprise
Communication Server (if available).
Syntax: [IP]:[port]
Example: 192.167.101.2:5060
The IP address and port of the group call server.
The group call server IP address is the local MCG 3100 IP
address with the port configured on the group call server page.
Syntax: [IP]:[port]
Example: 192.167.130.75:5072