Disposal - Hilti TE 6-A36 Operating Instructions Manual

Hide thumbs Also See for TE 6-A36:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
Fault
No hammering action.
en
The control switch can't be
pressed, i.e. the switch is
locked.
The drive spindle doesn't rotate.
The power tool switches itself
off automatically.
The battery runs down more
quickly than usual.
The battery doesn't engage with
an audible double click.
The power tool or the battery
gets very warm.
The insert tool can't be
released.
The tool makes no progress.

10 Disposal

CAUTION
Improper disposal of the equipment may have serious consequences: the burning of plastic components generates
toxic fumes which may present a health hazard. Batteries may explode if damaged or exposed to very high
temperatures, causing poisoning, burns, acid burns or environmental pollution. Careless disposal may permit
unauthorized and improper use of the equipment. This may result in serious personal injury, injury to third parties and
pollution of the environment.
CAUTION
Dispose of defective batteries without delay. Keep them out of reach of children. Do not attempt to open or dismantle
batteries and do not dispose of them by incineration.
CAUTION
Dispose of the batteries in accordance with national regulations or return them to Hilti.
26
Possible cause
The power tool is too cold.
The function selector switch is set to
"Drilling without hammering".
The forward/reverse switch is set to
reverse rotation.
The forward / reverse switch is in the
middle position (transport lock en-
gaged).
The permissible operating temper-
ature of the power tool's electronics
has been exceeded.
The permissible battery operating
temperature has been exceeded.
The battery is discharged.
The overload cut-out has been activ-
ated.
Battery condition is not optimal.
The retaining lugs on the battery are
dirty.
Electrical fault.
The power tool has been overloaded
(application limits exceeded).
The chuck is not pulled back fully.
The forward/reverse switch is set to
reverse rotation.
Remedy
Allow the power tool to warm up to
the minimum operating temperature.
See section: 7.2.1 Working at low
temperatures
Set the function selector switch to
"Hammer drilling".
Set the forward/reverse switch to for-
ward rotation.
Push the forward / reverse switch to
the left or right.
Allow the power tool to cool down.
Bring the battery to the recommen-
ded working temperature.
Change the battery and recharge the
discharged battery.
Release the control switch, reduce
the load on the power tool and then
press the switch again.
Have battery condition diagnosed by
Hilti Service or replace with a new
battery.
Clean the retaining lugs and check
that the battery engages securely.
Contact Hilti Service if the problem
persists.
Switch the power tool off immedi-
ately, remove the battery and contact
Hilti Service.
Use the right power tool for the job
(don't use a low-powered tool for
heavy work).
Pull the chuck back as far as it will go
and remove the insert tool.
Set the forward/reverse switch to for-
ward rotation.

Advertisement

Table of Contents
loading

Table of Contents