The floor-tool
The TTB range is provided with the aluminium floor-tool shown.
To clean the floor-tool, remove securing-pin and disconnect the lifting strap and remove the floor-tool securing pin
pull-free the floor-tool from the rear of the machine. Rinse the floor-tool assembly with clean-water and refit.
38
Periodically the floor-tool blades should be examined and checked for wear and damage.
The blade removal is easy. Simply start by removing the four retaining pins (see Fig.37), turn the floor-tool over and
separate the blade carrier from the body (see Fig.38). Peel away the blades from their locating lugs (see Fig.39) and
examine or renew as required. Replacement is a reversal of the removal process.
Floor-tool overview
1. Floor-tool main body
2. Rear blade
3. Blade carrier
4. Front blade (slotted)
5. Retaining pins x 4
Note: The blades are designed to be reversible, thus extending their useful working life.
Changing the Floor Tool Blades
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED
PRIOR TO ANY MAINTENANCE
37
39
1
2
3
4
5
36
!