Listing of Encoder Commands and Prompts

Command
Description
Program Identification, 4 digit HEX number (station "digital address")
PI
PS
Program Service Name, 8 (max) ASCII characters (station "street name")
Dynamic PS, 64 (max) ASCII characters (for messaging in PS field)
DPS
DPSS
Dynamic PS speed, 0 to 9 (0 = OFF, 1 = SLOW, 9 = FAST)
PTY
Program Type, 0 to 31 (describes station format)
Traffic Program, 0 or 1 (0 = NO, 1 = YES)
TP
Traffic Alert, 0 or 1 (0 = flag OFF, 1 = flag ON)
TA
DI
Decoder Information, 0 to 15
MS
Music/Speech, 0 or 1 (0 = speech-only, 1 = music)
TEXT
RadioText, 64 (max) ASCII characters
DRTS
Dynamic RadioText Speed, 0 to 9 (0 = OFF; 1 = SLOW 9 = FAST)
AFx
Alternative Frequencies List using method A, where x is from 1 to 7
0 = blank; 1 to 204 = "channel" in 87.6MHz to 107.9MHz
Example: AF1=10
TATIME
TA Timeout, 0 to 255 minutes (0 = OFF)
ECHO
Command Echo, 0 or 1 (0 = ECHO OFF, 1 = ECHO ON)
PARSE
Dynamic PS Method, 0 to 9
0 = centered, 9 = left justified, 1-8 = N characters at a time
MODE
Operating Mode, 0 or 1 (LOOP or SIDE) 0 = loop-through, 1 = sidechian
TIME
UTC Time, HH:MM:SS (HH=hour, MM=Minutes, SS=Seconds)
DATE
Date, DD.MM.YY (DD=Day, MM=Month, YY=YEAR)
OFFSET
Local Time offset, -15:30 to +15:30, in multiples of half hours
PHASE
RDS subcarrier Phase in degrees, 0 to 3599, 1 = 0.1 degree
CT
Switch transmission of 4A group ON or OFF, 0 = OFF, 1 = ON
Use '=' to SET parameter value, e.g.: PI=1234
Use '?' to GET parameter value, e.g.: TIME?
Command
Description
??
Returns all data in encoder memory
SER?
Returns device serial number
Returns firmware & hardware revision numbers
REV?
PILOT?
Returns the Status of the 19 kHz PLL.
LOCK - locked to the 19kHz stereo pilot signal.
FREE - defaulted to the internal timebase
RESET
Resets the encoder as if AC power were cycled off and on
INIT
Initializes the encoder to all factory defaults
CLS
Clears the Terminal Screen
Response
Meaning
OK
Command received by encoder properly formatted and understood
NO
Command properly formatted but data not understood
(NONE)
Data sent is ignored by the encoder
DON'T FORGET
be entered or changed easily through the Windows
SPECIAL COMMANDS
that all the static RDS registers, including simple scrolling messages, can
- 46 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
®
data entry screens.