Contents Introduction ............................6 Typographic conventions ........................7 General Information .......................... 8 Product Features ..........................9 Technical Specifications ........................ 10 Panel Indicators and Appointments ....................12 Front Panel............................ 12 Rear Panel ............................. 13 GPIO Connectors Pinouts ......................14 GPI Port Pinouts ........................14 GPI 1 Example Connection ......................
Page 3
IP address (IP). Represents IPv4 address................32 IP port (PORT). Represents IP port..................32 String (STR). Represents string.................... 33 Date (DATE). Represent date information................33 Time (TIME). Represent time information................34 Timer (TIMER). Represents relative time interval............... 34 Status page ............................
Page 4
WARRANTY TERMS AND CONDITIONS ................. 57 Product Registration Card ......................58 APPENDIX A ........................... 59 RDS: Europe vs America ......................59 The RDS System ........................... 59 APPENDIX B ........................... 60 How should I configure the connection between my DEVA Device and an FTP Client? 1.
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Introduction DEVA Broadcast Ltd. is an international communications and high-technology manufacturing organization, its corporate headquarters and facility located in Burgas, Bulgaria. The company serves the broadcast and corporate markets worldwide – from consumers and small businesses to the largest global organizations.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Typographic conventions This manual uses the following typographic conventions: Style Used for NOTE Important notes and recommendations Example Used when example text is cited “Menu”...
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com General Information DB9009-RX is our second generation Advanced IP Audio Decoder. This new addition to DEVA Broadcasting Tools is affordable, easy to use and furnishes more features than ever before. The powerful DSP processor allows accomplishing of the decoding process in real time.
Panel Indicators and Appointments FRONT PANEL 1. Phones Output - The following audio signals are reproduced through the headphones: - Voice Announcement of DB9009-RX IP Audio Decoder’s IP address upon startup; - Audio signal from the selected input. 2. LED Indicators...
COMPOSITE MPX LIMITER EQUALIZER Because of the all-digital, minimalist-discrete-component nature of device circuitry, we have not provided schematic diagrams of the DB9009-RX in this Manual. Please, note that: NO USER-SERVICEABLE COMPONENTS INSIDE. REFER ALL SERVICING TO QUALIFIED TECHNICAL PERSONNEL. - 15 -...
DEVA Broadcast Ltd. declines all responsibility if any one of the safety rules given herein is not observed. DEVA Broadcast Ltd. declines all responsibility if the end-user resells the product.
Use the device only with its top cover on to avoid electromagnetic anomalies. Otherwise, this may cause problems with the normal functionality of the unit; • For the normal remote operation of the unit, connect DB9009-RX to a good quality Internet connection; •...
Upon receipt, the equipment should be inspected for possible shipping damages. If such are found or suspected, notify the carrier at once and contact DEVA Broadcast Ltd. The original shipping carton box and packing materials should be kept for possible reuse, in case of return for Warranty repair, for example.
RADIO FREQUENCY INTERFERENCE Although we have made provision for DB9009-RX installation in the immediate proximity of broadcast transmitters, please do practice some care using the unit near abnormally high RF fields. - 18 -...
Using a cable ending with a standard XLR connectors connect DB9009-RX AES/EBU output to the digital audio input of your equipment. LAN PORT For normal operation it is necessary DB9009-RX to be connected to a local network or Internet by cable with RJ-45 connector. RS-232 COM PORT Using standart DB-9 cable connect DB9009-RX to any RS-232 compatible equipment.
Front Panel - OLED Display, Navigational & Soft Buttons DISPLAY The DB9009-RX’s OLED display has three function areas: Header, Soft Buttons and Main Screen Working area. HEADER AREA Header is located on the left quarter of the screen. Depending on contents of working area the header may contains the following items: 1.
The Menu Screen (shown below) appears after a short pressing of the [OK] Navigational Button. The DB9009-RX’s Menu Page contains selectable icons and buttons for selecting modes and functionalities of this device. Pressing [Left] and [Right] arrow buttons changes icon selection of the Menu Page.
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Operating Modes and Pages HOME PAGE Immediately after power-up and boot process of DB9009-RX, the Home page is shown on the display. Transition to Home page can be made from any page where Soft Button is available. On the default home screen the Header area is shown (see “Header Area”...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com GRAPHS PAGE Select Graphs icon from Menu page and short press [OK] button on it, or press the soft button labeled Graphs. The transition to Graphs page will be made. Graph page represents the value deviation of measured parameters in time.
Page 25
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com IP Audio 2 Left, measured in dB IP Audio 2 Right, measured in dB IP Audio 3 Left, measured in dB - 25 -...
Page 26
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com IP Audio 3 Right, measured in dB RTP Left, measured in dB RTP Right, measured in dB - 26 -...
Page 27
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com MP3 Player Left, measured in dB MP3 Player Right, measured in dB - 27 -...
Select Level icon from Menu page and short press [OK] button on it. The transition to Levels page will be made. Levels page shows bargraph representation of different parameters, measured by DB9009-RX. The parameters are shown in group of four. Each bargraph displays averaged momentary value in highlighted color number, minimum and maximum peak values.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com SETTINGS PAGE Select Settings icon from Menu page and short press [OK] button on it. The transition to Settings page will be made. The device settings are organized as hierarchical tree menu (Settings menu).
Page 30
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com • Menu complex parameter (such as Alarm) – the parameter editor is shown and edit mode is activated; [UP]/[DOWN] – If edit mode is active – changes the value of the selected parameter. Otherwise will move selection in corresponding direction up/down.
Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com There is several parameter types available in DB9009-RX. The way of editing depends of that type. Following is description of parameter types. Every parameter has several properties, change step, unit, default value, permitted range for its value and so on.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com String (STR). Represents string. Button assignments for STR in edit mode: [OK] – Accept the value and exits edit mode. Note that certain String, like e-mail addresses, are validated prior acceptation.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Time (TIME). Represent time information. Button assignments for TIME in edit mode: See DATE description. Timer (TIMER). Represents relative time interval. Button assignments for TIMER in edit mode: [OK] –...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com STATUS PAGE Information on the device’s status, IP address, etc. can be found here. ABOUT PAGE Information on the device’s model and contacts of the manufacturer can be found here. - 35 -...
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com WEB Interface DB9009-RX is controlled trough a build in WEB Server and a standard web browser can be used to monitor its status or to make some adjustments. To operate the device you need to know its IP Address.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com WEB Interface Menu pages STATUS Upon opening the WEB interface, the main Status window will appear. The page contains information on the device’s current status - the LED bar-graph representation of the left and right audio levels in dBFS, for the IP Audio Clients (1, 2, 3), RTP, MP3 player and Output.
Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com SETTINGS DB9009-RX provides you with a protected access to the device settings. In order to make the necessary adjustments to the device, please log in as an ADMINISTRATOR (username: admin, password: pass).
– Select decoder and sample rate. It can be set to Auto or manually set to a known decoder and sample rate. In Auto mode, the DB9009-RX will adjust decoder and sample rate, using stream supplied information. For PCM (uncompressed) sample rate can be 32 kHz, 44.1 kHz or 48 kHz.
If the audio from the main source disappears, the DB9009-RX will automatically switch to the first backup source; if it also fails, the unit will switch to the second. Once a source with higher priority is restored, the unit will switch back to it.
‘Jingles’ (no subfolders are allowed). The folder should be located in the root of the SD Card. The playlist file must be named playlist.m3u. For information on how the connection between the DB9009-RX and an FTP Client should be configured, please refer to “APPENDIX B”...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com DAYPARTS Dayparting is the practice of dividing the day into several parts, during which a different type of audio source will be used. This function will allow a broadcasting pattern based on the radio’s timetable to be made.
– Adjusts the modulation level of the RDS subcarrier as a component of the MPXsignal Phase Adjustment – The phase of the Pilot Tone, L-R sub-carrier (38 kHz) and RDS sub- carrier (57 kHz) are factory adjusted. Additional adjustments can be made by the user providing more flexibility in DB9009-RX settings. - 43 -...
Page 44
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com MPX Output – Select output level of the MPX signal. MPX ITU Limiter – Enable or Disable the MPX Limiter. Threshold –...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com BASIC RDS All basic elements of the RDS/RBDS are displayed on the screen – PI, PS, RT, TA/TP and etc. Alternative frequencies are also available, represented as a list.
Page 46
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com PTY (Program Type) – The PTY data flag identifies the station format from a pre-defined categories. Many RDS receivers are able to seek the listener’s preferred format automatically. This means that a car radio can switch from a fading station to a stronger one that carries the same variety of music, though not the very same program, as provided by AF switching.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com DYNAMIC RDS Dynamic PS ‘marches’ the message across the display screen one character at a time. The message requires a much longer transmission time in this mode, but a glance at the radio display a few seconds still allows the driver to get the full message without missing words.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com enable the more-popular, centered-auto-parsed block mode and 1 - Scroll by 1 letter the Dynamic PS, letter-by-letter option. Radio Text RT Speed – The Radio Text update rate is programmed by setting RT Speed =n , with n a number between 1 and 9, corresponding to a refresh rate between slow and fast, respectively.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com HOW TO CONNECT TO THE RDS CONSOLE The RDS console is used to edit the RDS settings in real time. It can be used with an automation software or a terminal program.
Command properly formatted but data not understood. Console has been inactive for more than 30 minutes and the connection will be dropped. User needs to connect again to enter more commands. (NO RESPONSE) Data sent is ignored by DB9009-RX. - 50 -...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com OUTPUT Analog Audio – set the level of the Analog Audio output (in dBu). Digital Audio– enable or disable the Digital Audio output. Headphones –...
– As a USER – that will allow you to just monitor the device, while all the settings remain locked. In order for the security of DB9009-RX to be enhanced, new username and password could be set from the Security section.
DHCP client to be activated, the function should be enabled. When the DHCP client is activated, all assigned values will be shown in the relevant fields on the “Status Screen”. If due to any reason, the DHCP procedure cannot be completed, DB9009-RX will use Auto IP and will generate an IP Address.
FTP Server Enable/Disable the FTP Server. Specify the Command and Data Ports to be used. For information on how the connection between the DB9009-RX and an FTP Client should be configured, please refer to “APPENDIX B” on page SNMP Agent Specify Agent ID, Agent Port, Read/Write Communities, Manager IP, Manager Port and AgentSession Time.
GPIO The general purpose outputs/inputs settings are applied through this page. UART Redirector Server - DB9009-RX also acts as Ethernet to RS-232 redirector. You can connect any RS-232 compatible equipment to DB9009-RX and communicate with it over the Internet. The option can be either [Enabled] or [Disabled].
[All except IP] – all settings except for the Network settings (IP addresses) will be deleted. To restore DB9009-RX to its factory defaults press the button. A new window will appear - confirm that you want to restore the factory defaults and wait for the process to be completed. On completion of the process, the settings should have the proper default values.
A. Equipment will not be accepted for Warranty or other repair without a Return Authorization (RA) number issued by DEVA Broadcast Ltd. prior to its return. An RA number may be obtained by calling the factory. The number should be prominently marked on the outside of the shipping carton.
Your signature* *Signing this warranty registration form you are stating that all the information provided to DEVA Broadcast Ltd. are truth and correct. DEVA Broadcast Ltd. declines any responsibility for the provided information that could result in an immediate loss of warranty for the above specified product(s).
For this, the reader is directed to the Specification appropriate to his location either the CENELEC EN50067 Specification for Europe or the United States NRSC Specification. Since the Manual will deal with specific implication of RDS implemented with the DB9009-RX, it is assumed that the user is familiar with the RDS concept.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com APPENDIX B HOW SHOULD I CONFIGURE THE CONNECTION BETWEEN MY DEVA DEVICE AND AN FTP CLIENT? In order for a connection to be established the following setting should be applied: 1.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com 3. Example of FTP Client (FileZilla) Settings In some cases, FileZilla’s “Quick connect” feature is not able to connect with the DEVA unit. That is why we recommend the device to be assigned in the program manually.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com APPENDIX C.1 PTY Code Description Used in RBDS Mode – North America Short Name Description News News reports, either local or network in origin. Information Programming that is intended to impart advice.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com APPENDIX C.2 PTY Code Description Used in RDS Mode – Europe, Asia PTY Short Name Description News Short accounts of facts, events and publicly expressed views, reportage and actuality. Current affairs Topical program expanding or enlarging upon the news, generally in different presentation style or concept, including debate, or analysis.
Need help?
Do you have a question about the DB9009-RX and is the answer not in the manual?
Questions and answers