List of available RDS console commands and their responses

PARAMETER
INIT
Program Identification
Program Service
Dynamic PS
Dynamic PS Speed
Dynamic PS Method
PTYN
Program Type
Traffic Program
Traffic Alert
Alternative
frequencies
Decoder Information
Music/Speech
Radio Text
Radio Text Speed
Command Echo
CT group 4A control
PTYN group 10A control
AF count
SPECIAL COMMAND MEANING
=
?
??
INIT
RESPONSE
MEANING
HELLO
Welcome message when connection to the console is established. If security is
enabled proceed with entering the password. Otherwise proceed with commands.
PASS?
Password request. Will appear if such os set.
PASSOK
Password accepted, may proceed with commands.
PASSFAIL
Wrong password. Connection is dropped immediately
OK
Command received by encoder properly formatted and understood.
NO
Command properly formatted but data not understood.
BYE
Console has been inactive for more than 30 minutes and the connection will be
dropped. User needs to connect again to enter more commands.
(NO RESPONSE)
Data sent is ignored by DB9009-RX.
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
COMMAND DATA ENTRY
INIT
Applies the default settings.
PI
4 digit HEX number (station "digital address")
PS
8 (max) ASCII characters (station "street name")
DPS
64 (max) ASCII characters (for messaging in PS field)
DPSS
0 to 9 (0 = Off, 1 = slow, 9 = fastest)
PARSE
0 through 9 (0 = parsed, centered; 1-8 = Safe Scrolling; 9
= parsed, left)
PTYN
Sets Program Type Name
PTY
1 or 2 digit number (describes station format)
TP
0 or 1 (0 = no, 1 = yes)
TA
0 or 1 (0 = flag off, 1 = flag on)
AF
0 to 204 (0 = blank; 1 to 204 = "channel" in 100 kHz
increments, 87.6 MHz to 107.9 MHz)
DI
1 digit HEX number
MS
0 or 1 (0 = speech-only, 1 = music)
TEXT
64 (max) ASCII characters
DRTS
0 to 9 (0 = RadioText off; 1 to 9 = update rate, slow to fast)
ECHO
0 or 1 (0 = echo off, 1 = echo on)
CTON
0 (disbles) or 1 (enables) type 4A Group Transmission
PTYNON
0 (disbles) or 1 (enables) type 10A Group Transmission
AFCOUNT
Sets the numbers of AFs transmitted.
Set parameter value. Following a parameter command sets new value to
that parameter; e.g.: PI=1234
Get parameter value. Following a parameter command returns status of
encoder memory for that parameter; e.g.: AF3?
Returns all data in encoder memory.
Initializes the encoder to all factory defaults.