The next window that appears shows selected COM Properties. Here you set the communications
parameters as follows: Bits per second: 9600, Data bits: 8, Parity: None, Stop bits: 1, Flow control:
None. Check your settings against the screen shot. Click OK to close all boxes and to clear the
HyperTerminal data entry screen.
If you experience trouble communicating with the SmartGen Micro, there's a quick and easy
check to verify that the computer and the terminal program are functioning normally. With pins 2
and 3 of the DB-9 connector shorted with a screwdriver, whatever is typed on the keyboard should
appear on the screen.
When COM port setup is complete the computer may be connected to the encoder COM port.
Next, skip to Power-Up, below.