Data Interconnection; Usb Port; Computer Or Terminal Requirements - DEVA Broadcast SmartGen Micro Maintenance And Operation Instruction Manual

Basic rds/rbds encoder with usb connectivity
Hide thumbs Also See for SmartGen Micro:
Table of Contents

Advertisement

USB PORT

Front-panel USB port, convenient for setting service flags and entering static RDS data
NOTE: For USB interface with a PC for local programming of the 'static' data registers,
software must be installed on the computer before it is connected to the encoder. Refer to software
installation instructions beginning in section "Programming Options" on page 26.
ASCII Communication syntax is explained in section "ASCII Programming Syntax" on page 43.

COMPUTER OR TERMINAL REQUIREMENTS

For fast and easy encoder programming via the serial USB port, Windows
Entry Software routines have been supplied on a CD-ROM. This software also may be downloaded
from the DEVA Broadcast Ltd. Website. Alternatively, the encoder may be addressed with any
computer running a 'terminal emulation' program (e.g.: HyperTerminal, normally supplied with
®
Microsoft Windows
Static PS and other IDs, flags, the Alternative Frequency list and operating mode options are
uploaded into non-volatile encoder memory from a PC with USB connection. If Dynamic PS or
RadioText messaging is not used, a slogan, phone number or advertising messages can also be
entered manually into the 64-character Dynamic PS and RadioText fields. These will be displayed
on the radio faceplate as a repetitive scrolling-PS or static RadioText messages. Keep in mind that
RadioText and Dynamic PS are separate functions, both of which are simultaneously available
with the SmartGen Micro.
Once static data has been uploaded, the encoder may be disconnected from the computer,
relocated to another operating point, or reconnected to an alternative data source for dynamic
messaging. This may be a hard-disk-based station automation system that provides song title and
artist, plus ads or station promos. The automation system must be configured to the encoder's
communication port and programmed to deliver dynamic data in proper syntax as explained by the
instructions in section "ASCII Programming Syntax" on page 43.

Data Interconnection

XP).
- 23 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
®
-based RDS Data-