10. Slide the shuttle release latch toward the left side of the server, and push the
11. Lift the shuttle out of the server.
12. If you are instructed to return the shuttle assembly, follow all packaging

Installing the system board and shuttle

Notes:
1. When you reassemble the components in the server, be sure to route all cables
2. When you replace the system board, you must either update the server with the
To reinstall the system board and shuttle, complete the following steps.
v The ServeRAID SAS controller (see "Removing the ServeRAID SAS
controller" on page 102)
Important: Note which DIMMs are in which connectors, before you remove the
DIMMs. You must install them in the same configuration on the replacement
system board.
5. Remove all DIMMs, and place them on a static-protective surface for
reinstallation (see "Removing a memory module (DIMM)" on page 114).
6. Disconnect all cables from the system board.
7. Slide the power supplies out of the bays slightly or remove them entirely (see
"Removing a hot-swap power supply" on page 118).
8. Slide the power backplane toward the right side of the server (see "Removing
the power backplane" on page 126).
Attention:
In the following step, do not allow the thermal grease to come in
contact with anything, and keep each heat sink paired with its microprocessor
for reinstallation. Contact with any surface can compromise the thermal grease
and the microprocessor socket; a mismatch between the microprocessor and
its original heat sink can require the installation of a new heat sink instead.
9. Remove the VRM and each microprocessor heat sink and microprocessor;
then, place them on a static-protective surface for reinstallation (see
"Removing a microprocessor" on page 134).
shuttle toward the rear of the server approximately 12.7 mm (0.5 inch).
instructions, and use any packaging materials for shipping that are supplied to
you.
carefully so that they are not exposed to excessive pressure.
latest firmware or restore the pre-existing firmware that the customer provides
on a diskette or CD image.
Chapter 4. Removing and replacing server components
141