LYNXR-ISIA Installation and Setup Guide
Data Field Descriptions
Report Format for Primary/Secondary
48
Primary
See choices below
0 = 3+1; 4+1 ADEMCO Low Speed Standard
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Low Speed Standard
3 = 4+2 Radionics Standard
5 = ADEMCO Contact ID® Reporting with 10-digit
subscriber account number
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID® Reporting with 4-digit
subscriber account number
8 = 3+1; 4+1 ADEMCO Low Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
Split/Dual Reporting
49
To Primary
0 = All reports
1 = Alarms, Restore, Cancel*
2 = All except Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test
5 = All reports
To Primary
6 = All reports except Open/Close
7 = All reports
8 = All reports
9 = All reports except Open/Close
To Primary
10=All reports except Open/Close
11 = All reports
12=All reports
13=All reports except Open/Close
*Recent close report is sent to primary number
‡ Will report Users 0, 5-8, and, if using wireless button-type
devices, will report the zone number of the arm or disarm
button 26-33. All other zones and users are not reported.
Burglary Abort Window
50
1 = 15-second abort window
2 = 30-second abort window
3 = 45-second abort window
Periodic Test Report
51
0 = no test report
1 = once every 24 hrs
Secondary
See choices below
To Secondary
None, unless primary
fails, then all
Others
Open/Close, Test
All
All
All
To Paging Number
Alarms, Open/Close ‡ ,
Troubles
Alarms, Troubles
Alarms, Open/Close ‡ ,
Troubles
Open/Close ‡
To Follow Me System
Phone Number
Alarms, Open/Close ‡ ,
Troubles
Alarms, Troubles
Alarms, Open/Close ‡ ,
Troubles
Open/Close ‡
2 = weekly
3 = once every 30 days
Enter ✻ as the 4th digit of ✻ 43 through ✻ 44, if 3+1 dialer
reporting is to be used. (For an explanation of these formats, see
the System Communication section of this manual.)
Notes: (1) The maximum number of alarm and alarm restore
reports during one armed period is determined by field
✻ 92.
(2) If Option 5 is selected a 10-digit account number must
be entered in Fields ✻ 43 or ✻ 44.
(3) Option 5 or 7 (ADEMCO Contact ID® Reporting) must
be selected for AVM.
This field is used to select a reporting option as follows:
Enter: 0 - 5 when reporting to telephone receivers.
6 - 9 when reporting to a pager is desired.
10 - 13 when reporting to an auxiliary telephone receiver.
Pager Report Format
Options 6-9 send reports to the primary phone number, in a
format defined in Field ✻ 48, and send reports to a pager, which
has its phone number entered as the secondary phone number in
Field ✻ 42. The pager report is a 7-digit code, with optional 16-
digit prefix, in the following format:
AAAAAAAAAAAAAAAA-EEE–0NNN where:
AAA = Optional 16 digits for PIN number, etc. See Field ✻ 88 for
full description of these characters.
EEE = 3-digit Event Code as follows:
911 = Alarm (NN = zone number)
101 = Open, system disarmed (NN = user no.)
102 = Close, system armed (NN = user no.)
811 = Trouble (NN = zone no.)
0 =
Always displayed before 3-digit user/zone no.
NNN = 3-digit user number or zone number, depending on the
type of event (EEE) that occurred.
Follow Me System Report Format
Options 10-13 send reports to the primary phone number, in a
format defined in Field ✻ 48, and sends voice message to the
secondary phone number entered in Field ✻ 42.
The message is a repeatable system status announcement. If the
manual paging option has been programmed in Field ✻ 87, the
message will repeat "system, system.....".
The message can be terminated by pressing any key on the
telephone keypad.
This provides the option for an Abort Window for Burglary zone types that
report to the central station. This feature allows time for the subscriber to
avoid a false alarm transmission. This feature does not apply to zone type 9
or 16 alarms (Supervised Fire) or to 24-hour zone types 6, 7, and 8 (silent
panic, audible alarm, auxiliary alarm), which are always sent as soon as they
occur.
SIA The burglary abort window must be set to a minimum of 15
seconds. The sum of the burglary abort window entered in ✻50 and
the entry delays entered in either Field ✻35 or ✻36 should not
exceed 1 minute.
Note: The control validates the data entered in this field. If the selection is
not valid the control will emit a single long beep indicating that the
selection has been rejected. The control replaces the selection with
the default value "2", which is displayed on the keypad, and
advances to the next field.
Test report code entered in field ✻ 64 is sent.