Honeywell ADEMCO LYNXR-ISIA Installation And Setup Manual page 33

Table of Contents

Advertisement

✻ 56 Enhanced Zone Programming Mode
Loop number or Loop and Serial
l
E
number (if using RF Learning)
1-4 = loop number for the zone of the transmitter
being entered.
0 + [✻] = continue to DELETE ZONE
PARAMETERS CONFIRMATION prompt
(F)
[✻] = continue to the ENROLL MODE prompt
(1A) if not entered, or VOICE DESCRIPTOR
prompt if already entered
[#] = return to previous prompt
Delete zone parameters confirmation
F
0 = discard the delete request
1 = confirm requested delete
Note: If 00 was entered as a zone type in prompt (b), 00
will be retained and system will advance to
prompt (1C).
LYNXR-ISIA Installation and Setup Guide
This prompt can be used to enroll loop number and serial number via
RF transmission or the loop number can be enrolled manually. If
using the RF Learning Mode, there is no need to manually enter a
loop number. Proceed directly to RF Learning
Notes: (1) BR type devices cannot be enrolled by using UR or RF
type. Likewise, UR or RF type devices cannot be enrolled
by using a BR type device. There is a 52-second time-out
for RF enrolling. At the end of the time-out, the system
returns to the INPUT TYPE prompt (d). If enrolled, loop
number and "L" are displayed.
(2) Once encrypted (high-security) devices have been enrolled
they must be activated. Refer to the device's Installation
Instructions to activate the High-Security Mode. RF
Learning - Two (2) transmissions (2 key depressions) at
least 5 seconds apart will be required for BR type devices
(device type 5). Two beeps will sound after the second
transmission, confirming that the loop number and serial
number have been learned.
For all other device types, four (4) transmissions are required (fault,
restore and fault, restore). A single beep will sound after the second
transmission confirming that the loop and serial number have been
captured. Following the fourth transmission the system will confirm
that the loop number and serial number have been learned and
announce the Voice Descriptor for the zone, if it is programmed,
followed by two beeps.
Press [
] to continue.
Manual Entry - Enter the desired loop number and press [
continue (see the transmitter's Installation Instructions for specific
loop designations).
Note: The loop number can be changed even if the zone has already
been entered. Care should be taken when using this feature as
it has the capability to make zones inoperable by creating a
mismatch of a working serial number/loop number
combination. This should be re-confirmed if the loop number is
changed.
"L" indicates that the zone's serial number has already been enrolled.
This function deletes either the serial number or all zone information
that is programmed for the zone.
If "00" was entered in the zone type, the confirmation of the delete
request will delete all information associated with the zone currently
being programmed.
If "0" was entered in the loop number, the confirmation of the delete
request will delete the serial number of to the zone currently being
programmed.
- 33 -
] to

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents