Honeywell ADEMCO LYNXR-ISIA Installation And Setup Manual page 66

Table of Contents

Advertisement

LYNXR-ISIA Installation and Setup Guide
Programming Default Tables
Function
*89 Event log 80% full report code
*90 Event logging
*91 Alarm audio verification/remote phone control
*92 Swinger shutdown
*93 Flexible call back
*94 Download phone number
*95 Ring detect count for downloading/remote phone control
Default Master Code
Default Duress Code
By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15.
✻56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 1
Zone No.
Zone Type
Alarm Code
2
1
3
1
4
3
5
10
26
21
27
22
28
20
29
23
30
21
31
22
32
20
33
23
92
---
99
6
NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic
✻56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 2
Zone No.
Zone Type
Alarm Code
2
1
3
1
4
1
5
04
6
9
26
21
27
22
28
20
29
23
30
21
31
22
32
20
33
23
92
---
95
08
96
09
99
07
NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zones 95, 96 and 99 are keypad panics
(boldface indicates defaults that differ between tables)
Table 1
0,0
3
2
1
0
---
15
1,2,3,4
---
Input Type
Loop Number
1,0
3 (RF)
1,0
3 (RF)
1,0
3 (RF)
1,0
3 (RF)
1,0
5 (BR)
1,0
5 (BR)
1,0
5 (BR)
0,0
5 (BR)
1,0
5 (BR)
1,0
5 (BR)
1,0
5 (BR)
0,0
5 (BR)
---
---
1,0
---
Input Type
Loop Number
1,0
3 (RF)
1,0
3 (RF)
1,0
3 (RF)
1,0
3 (RF)
1,0
3 (RF)
1,0
5 (BR)
1,0
5 (BR)
1,0
5 (BR)
0,0
5 (BR)
1,0
5 (BR)
1,0
5 (BR)
1,0
5 (BR)
0,0
5 (BR)
---
---
1,0
---
1,0
---
1,0
---
- 66 -
Table 2
Table 3
0,0
0,0
15
3
2
2
1
1
0
0
---
---
15
15
1,2,3,4
1,2,3,4
---
---
Zone Descriptor
2
47, 04 (FRONT DOOR)
2
33, 04 (BACK DOOR)
2
80 (WINDOW)
1
56 (MOTION DETECTOR)
3
2
4
1
3
2
4
1
---
---
Zone Descriptor
2
47, 04 (FRONT DOOR)
2
33, 04 (BACK DOOR)
2
48, 04 (GARAGE DOOR))
1
56 (MOTION DETECTOR)
1
22, 02 (SMOKE DETECTOR)
3
2
4
1
3
2
4
1
---
---
---
---
Table 4
0,0
3
2
1
0
---
15
1,2,3,4
---

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents