First test Report Offset
52
0 = 24 hrs after exit program mode or download
1 = 6 hours after exit program mode or download
2 = 12 hrs after exit program mode or download
3 = 18 hrs after exit program mode or download
Sescoa/Radionics Select
53
0 = Radionics (0–9, B–F reporting)
1 = SESCOA (0–9 only reporting)
Lack of Usage Notification
54
0 = Disabled
1 = 1 day
2 = 7 days
3 = 27 days
Note: There is no local annunciation indicating that this
report has been sent to the Central Station.
Enable/Disable LRR/IP Communications
55
Device
0 = disable
1 = enable
False Alarm Options
57
Cancel
Alarm
Value
Display
0 =
Disabled
1 =
Disabled
2 =
Disabled
3 =
Disabled
4 =
Enabled
5 =
Enabled
6 =
Enabled
7 =
Enabled
RF Jam Detection
58
0 = no jam detection
1 = RF jam detection with event logging, but no
central station report
2 = RF jam detection with event logging and with
central station report (if trouble/restore report is
enabled in fields ✻60, ✻71)
4 = 90 days
5 = 180 days
6 = 365 days
Exit Time
Auto Stay
Restart/
Arming
Reset
Disabled
Disabled
Disabled
Enabled
Enabled
Disabled
Enabled
Enabled
Disabled
Disabled
Disabled
Enabled
Enabled
Disabled
Enabled
Enabled
- 25 -
LYNXR-ISIA Installation and Setup Guide
Data Field Descriptions
Select the time for the first report following programming or
downloading.
If disabled, selects Radionics, which uses hexadecimal 0-9, B-F
reporting.
If enabled, selects Sescoa, which uses only numeric reporting (0-9).
Select 0 for all other formats.
If enabled, notifies the central station if an end user is not
operating their security system by sending a System Inactivity
report 654. The report will be sent only to the Primary phone
number and only if Contact ID® format was selected.
Note: The report will follow the ✻ 49 = 0 rules, no matter which
selection was made in ✻ 49.
This option is used to enable/disable Central Station reporting via
the LRR/IP Communications Device (See Field *77). Upload/
download via the Internet IP module is not affected by this entry.
Zone 103 supports the LRR/IP Communications Device.
Notes: (1) When LYNXR-ISIA is in programming mode it will not
communicate with the LRR/IP device. As a result the
LRR/IP device will transmit 355 (event and restore)
reports to the Central Station.
(2) Zone 103 can not be bypassed.
Note: The control validates the data entered in this field. If the selection is
not valid the control will emit a single long beep indicating that the
selection has been rejected. The control replaces the selection with
the default value "7", which is displayed on the keypad, and
advances to the next field.
Cancel Alarm Display
This option enables the display of aborted and cancelled alarms on the
LYNXR-ISIA keypad. "CA" will be displayed.
Notes: 1. An abort occurs if the alarm panel is disarmed before it dials the
alarm report to the central station.
2. A cancel occurs if the alarm panel is disarmed after the alarm is
reported.
3. Zone types 5, 6 and 7 (panic zone types) and 24 (silent burglary)
cannot be cancelled.
Auto Stay Arming
If this feature is enabled and the control panel has been armed "Armed
Away" at the LYNX keypad or RF keypad, the system will switch to the
"Armed Stay" mode if the Exit Time has expired and no exit has been
made.
Exit Time Restart-Exit Delay Restart/Reset
This option allows the systems to restart the exit delay time
after arming in STAY mode by entering the User Code and pressing the
STAY key (if quick arming is disabled) or by pressing the STAY key (if
quick arming is enabled). This option also enables automatic exit delay
reset, which resets exit delay if the entry/exit door is re-opened and closed
before exit delay time expires after arming.
Notes: 1. This avoids the need to disarm and then re-arm the system after
allowing someone to enter or exit.
2. Automatic Exit Delay Reset occurs only once during an armed
period.
For Event Logging, Option 2 must be selected.
If the control detects an RF Jam condition, a "FAULT" message
appears for zone 90. The Contact ID® code for RF Jam is 344.