LYNXR-ISIA Installation and Setup Guide
Data Field Descriptions
Confirmation of Arming Ding
38
0 = no arming confirmation ding after arming system by
LYNXR keypad or RF keypad
1 = arming confirmation ding after arming system by
LYNXR keypad or RF keypad
2 = arming confirmation ding after arming from RF
keypad only
Cross Zone Timer
39
Value
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
# + 10 =
# + 11 =
# + 12 =
# + 13 =
# + 14 =
# + 15 =
DIALER PROGRAMMING (
42: Enter up to the number of digits shown. Enter 0–9, # + 11 for ' * ' ; # + 12 for '#'; # + 13 for a pause
Fields
40,
41,
(2 seconds)
NOTE: Whenever AAV is used, primary (field ✻41) and secondary (field ✻42) phone numbers should be preceded with the
call waiting disable command. Otherwise, there is the possibility of connection of the third party to LYNXR-ISIA
during AAV mode.
PABX Access Code/Call Waiting Disable
40
Enter up to 6 digits if PABX is needed to access an
outside line.
or
Enter"# + 11 + 7 + 0" to program the touch-tone
sequence "*70" and cancel call waiting.
Primary Phone No.
41
Enter up to 20 digits.
Time Window
No Cross Zoning
15 seconds
30 seconds
45 seconds
60 seconds
1 minute, 15 seconds
1 minute, 30 seconds
1 minute, 45 seconds
2 minutes
2 minute, 15 seconds
2 minute, 30 seconds
2 minute, 45 seconds
3 minutes
3 minute, 15 seconds
3 minute, 30 seconds
3 minute, 45 seconds
40–
50)
Confirmation of arming is provided by a 1/2 second external sounder
"ding" .
The confirmation ding only sounds when LYNX is Armed Away or
disarmed after being Armed Away.
If Option 1 is selected, confirmation of arming is provided by a 1/2 second
sounder "ding" that sounds when closing report is sent, or at the end of
exit delay.
If Option 2 is selected the external sounder "ding" occurs immediately
after arming from an RF keypad.
Note: If LYNX is armed by RF button (key fob), a confirmation ding
occurs immediately after arming regardless of field *38 settings. If
LYNX is disarmed by RF button (key fob), additional disarming
confirmation ding is provided. The ding occurs immediately after
disarming and is longer than arming confirmation ding.
Sets the maximum amount of time in which two cross zones must be
tripped in an armed system to send an alarm message to the Central
Station. If only one cross zone is tripped during this time, a trouble
message (CID code 380) for that zone is sent to the Central Station.
Program Zone list 2 (using *81 Zone List Menu Mode) with the two
zones that are to be cross zoned.
Notes: (1) If option
39 is set to "0" (no cross zoning) then Zone List 2
can be used for other purposes.
(2) Cross zoning will be disabled during entry and exit delays,
if there is already an alarm in the system, if one or both of
the 2 cross zones is bypassed.
If one of the 2 cross zones faults and remains faulted after
the cross zone time interval, the second cross zone can go
into alarm immediately, even after the cross zone time.
This is to detect scenarios involving multiple break-ins of a
premises.
UL This option is not for use in UL installations.
If fewer than 6 digits need to be entered, exit by pressing [
✻40✻
entries from field, press
Call Waiting: If the subscriber's phone service has "call waiting" (and is
not using PABX), enter the touch-tone sequence"*70" (or similar
depending on the phone service). by programming "# + 11 + 7 + 0" as the
PABX entry to disable "call waiting" during control panel calls. You
must also enable the Call Waiting Cancel option in field *47.
If the subscriber does not have "call waiting" and is not using PABX,
make no entry in this field.
Important Note: If Call Wait Cancel is disabled in Field ✻47, and Call
Wait Disable command is entered in Field ✻40, this
will prevent successful communication to the central
station when used on a non-call waiting line.
Note: PABX number and operation of the control panel with a PBX
system cannot be used if the Call Waiting Cancel Disable option
has been enabled in Field ✻47.
If fewer than 20 digits entered, exit by pressing [ ✻ ]. To clear
entries from field, press ✻ 41 ✻ .
Note: Backup reporting (8 attempts are made to the secondary
phone number if no kissoff is received after 8 attempts to
the primary number) is automatic only if there is a
secondary phone number (field ✻ 42).
- 22 -