Room-Size Table; Appliance Location - Prolitec Air/Q 310 User Manual

Table of Contents

Advertisement

Installation

Room-Size Table

Output
Level Range
1 thru 5
6 thru 10
11 thru 15
16 thru 20
21 thru 25
26 thru 30
31 thru 35
36 thru 40
41 thru 45
46 thru 50
These settings are suggested as a starting point. Start on the lower end of the
range and adjust after 15 minutes. Room size, number of fresh air changes per
hour, temperature, humidity and user preference will determine the final setting.

Appliance Location

1. Placement of Air/Q
It is important to identify a wall or track-light location where the output of
Air/Q 310 can use, rather than fight, the natural air currents in a room.
2. Air currents in a room are determined by using a SMOKE TEST KIT available
from Prolitec or any source of smoke or vapor, such as a candle or match.
3. To conduct a smoke test, stand at the entrance of the room in front of the door
and observe the direction of the smoke or vapor. If the smoke drifts into the
room Air/Q 310 appliance should be installed somewhere near the door.
Room Volume
Range in CFT
200 – 800
1,000 – 1,700
1,900 – 2,800
3,000 – 4,000
4,200 – 5,300
5,600 – 6,800
7,200 – 8,600
8,900 – 10,500
10,900 – 12,600
13,100 – 15,000
310 appliance is the KEY TO OPTIMAL PERFORMANCE.
Room Volume
Range in m
3
6 – 23
28 – 48
54 – 79
85 – 113
119 – 150
159 – 193
204 – 244
252 – 297
309 – 357
371 – 425
7