Prolitec Air/Q 1100-Avian User Manual

Air/q1100a

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Air/Q 1100-Avian and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Prolitec Air/Q 1100-Avian

  • Page 2: Table Of Contents

    Table of Contents Air/Q 1100-Avian User Guide I. Introduction to Air/Q 1100-Avian ......................1 II. Safety Precautions ..........................2 A. Appliance Precautions B. Avian Plus Fragrance Precautions III. Appliance and Controls ........................3 IV. General Maintenance .......................... 4 A. Changing the Cartridge B.
  • Page 3 System maintenance is minimal and limited to periodic fragrance cartridge replacement and surface cleaning. This is calculated using the formula for the volume of a sphere where V is the volume or weight and r is the radius of the droplet. Air/Q 1100-Avian User Guide © 2010 Prolitec, Inc.
  • Page 4: Safety Precautions

    If there is contact with the eyes, irrigate the eye with fresh water for 5 minutes. If there is any eye irrita- tion, consult a physician immediately. 4. Cartridges must be provided by and contain formulations which have been certified by Prolitec. Air/Q 1100-Avian User Guide...
  • Page 7: General Maintenance

    3. Insert the new CR2032 battery. The positive side of the battery should face your right while looking at the front of the appliance. The battery will have a + or – marking on a side. Air/Q 1100-Avian User Guide © 2010 Prolitec, Inc.
  • Page 8: Commissioning The Air/Q 1100-Avian

    Commissioning the Air/Q 1100-Avian V. Commissioning the Air/Q 1100-Avian A. Getting Started 1. Open the door and unlock if needed. 2. Turn on the power by pressing the ON/OFF button in the upper left corner of the control panel. (Make sure the appliance is plugged in to the AC power outlet.) The power button will light blue.
  • Page 9: Bird Control General Considerations

    The rule of thumb is that one (1) Air/Q 1100-Avian will service UP TO 150,000 cubic feet. So you will need at least one appliance for every 150,000 cubic feet. If the air flows are unusually strong with a lot of fresh air, you may need more machines.
  • Page 10 Bird Control General Considerations E. Programming the Air/Q 1100-Avian Programming is simple from instructions on the machine itself. Basically, you can program start and stop times and the intensity level. 1. Scent intensity can be adjusted from 1 to 50. Turn the power on and use the +- keys to change inten- sity.
  • Page 11: Installation: Fragrance Director Attachment

    The Air/Q 1100 Avian may also be installed to diffuse via an HVAC system. This is an uncommon installa- tion for reaching bird roosting areas, but for those situations, installation instructions for HVAC diffusion are provided at the end of this manual. A. Direct Indoor Fan B. Diffusion Director Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 12: Installation: Direct Indoor Fan

    VIII. Installation: Direct Indoor Fan A. Installation Kits • Installation Kit for Appliance (included) 1. One (1) Air/Q 1100-Avian appliance (not pictured) with: 2. Four (4) dry wall anchors for mounting in drywall 3. Four (4) lead anchors for mounting in concrete 4.
  • Page 15: Diffusion Fan Installation

    (Fig. 8) Fold into an “L” shape and peel off liner. (Fig. 9) Fasten adhesive side to the wall between appliance and Diffusion Fan assembly. Fig. 7 Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 16 8. Extend the hose from appliance toward the Diffusion Fan hose barb, cut to proper length (Fig. 13) and secure to the hose barb of the Diffusion Fan assembly. (Fig. 14) 9. Turn the APPLIANCE on and verify that a plume is produced. Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 19: Installation: Diffusion Director

    6. Lube the inside of the grommet if needed to allow the Injector hose to easily slide through. Leave ap- proximately 2 inches of hose length inside the appliance to provide enough play when replacing the cartridge. Tighten aluminum cap of waterproof collar to ensure a watertight seal. Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 21 Make sure the bent aluminum tube is pointing in the direction of the unit, and that the elbow and reducer point towards the center of the room. (Fig. 23) Fig. 23 Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 22 (P/N 6614) and washers (P/N 10605). Connect the fan power cord to the connector in the con- trol box. For mounting in concrete, drill 5/16” holes. Secure using anchors (P/N 10439), screws (P/N 10440), and washers (P/N 10605). (Fig. 27) Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 23 Also, check to make sure that the fan is running. This can be done by holding your hand below the fan and feeling for air flow. Reconnect the black injector hose. (Fig. 29) Fig. 29 Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 24: Installation Kit

    VIII. Installation: Diffusion via HVAC System A. Installation Kits • Installation Kit for Appliance (included) 1. One (1) Air/Q 1100-Avian appliance (not pictured) with: 2. Four (4) dry wall anchors for mounting in drywall 3. Four (4) lead anchors for mounting in concrete 4.
  • Page 27: Appliance Installation

    45 upward. Turbulence in the airflow can prevent even aspiration of the plume. It is best to place the tube in a straight section of duct, and Air/Q 1100-Avian User Guide © 2010 Prolitec, Inc.
  • Page 28 Injector Tube until aspiration is achieved. 7. Attach the Injector hose onto the hose barb of the Injector Tube. For Cartridge Installation – See “Changing the Cartridge” in the General Maintenance section. Air/Q 1100-Avian User Guide © 2010 Prolitec, Inc.
  • Page 29: Troubleshooting

    Timer cycle. cycle on. If the real problem is that the scent or you cannot hear the cannot be detected, increase the output rate as compressor in the instructed above. appliance. Air/Q 1100 Avian User Guide © 2010 Prolitec, Inc.
  • Page 30: General Care And Customer Support

    888.615.9282). • Do not drop Air/Q 1100-Avian on the floor. Do not drop it in or position it near an open basin of water. • Do not paint or otherwise try to alter the color of the outer cover.
  • Page 31: Specifications

    Specifications XII. Specifications Air/Q 1100 Appliance Technical Characteristics Reference Air/Q 1100-Avian : Model AQ1100 Type 1 head nebulizer integrated with cartridge Diameter of particles 300 nm to 1µ micron Power Input Input 100 – 240 VAC at 0.6 A Frequency...
  • Page 32 Wall mount: 4 inch brackets, dry wall mounting screws and anchors, cement screws and anchors Approvals Fan motor conforms to ANSI/UL STD 705 Fan motor certified to CSA STD C22.2 NO 113 Environment Indoor only Cartridge Reservoir - 1250ml Disposable/Recyclable Patented Prolitec Inc. Multiple patents pending...

Table of Contents