Table of Contents Air/Q 1100-Avian User Guide I. Introduction to Air/Q 1100-Avian ......................1 II. Safety Precautions ..........................2 A. Appliance Precautions B. Avian Plus Fragrance Precautions III. Appliance and Controls ........................3 IV. General Maintenance .......................... 4 A. Changing the Cartridge B.
If there is contact with the eyes, irrigate the eye with fresh water for 5 minutes. If there is any eye irrita- tion, consult a physician immediately. 4. Cartridges must be provided by and contain formulations which have been certified by Prolitec. Air/Q 1100-Avian User Guide...
Commissioning the Air/Q 1100-Avian V. Commissioning the Air/Q 1100-Avian A. Getting Started 1. Open the door and unlock if needed. 2. Turn on the power by pressing the ON/OFF button in the upper left corner of the control panel. (Make sure the appliance is plugged in to the AC power outlet.) The power button will light blue.
The rule of thumb is that one (1) Air/Q 1100-Avian will service UP TO 150,000 cubic feet. So you will need at least one appliance for every 150,000 cubic feet. If the air flows are unusually strong with a lot of fresh air, you may need more machines.
Page 10
Bird Control General Considerations E. Programming the Air/Q 1100-Avian Programming is simple from instructions on the machine itself. Basically, you can program start and stop times and the intensity level. 1. Scent intensity can be adjusted from 1 to 50. Turn the power on and use the +- keys to change inten- sity.
VIII. Installation: Direct Indoor Fan A. Installation Kits • Installation Kit for Appliance (included) 1. One (1) Air/Q 1100-Avian appliance (not pictured) with: 2. Four (4) dry wall anchors for mounting in drywall 3. Four (4) lead anchors for mounting in concrete 4.
VIII. Installation: Diffusion via HVAC System A. Installation Kits • Installation Kit for Appliance (included) 1. One (1) Air/Q 1100-Avian appliance (not pictured) with: 2. Four (4) dry wall anchors for mounting in drywall 3. Four (4) lead anchors for mounting in concrete 4.
888.615.9282). • Do not drop Air/Q 1100-Avian on the floor. Do not drop it in or position it near an open basin of water. • Do not paint or otherwise try to alter the color of the outer cover.
Specifications XII. Specifications Air/Q 1100 Appliance Technical Characteristics Reference Air/Q 1100-Avian : Model AQ1100 Type 1 head nebulizer integrated with cartridge Diameter of particles 300 nm to 1µ micron Power Input Input 100 – 240 VAC at 0.6 A Frequency...
Page 32
Wall mount: 4 inch brackets, dry wall mounting screws and anchors, cement screws and anchors Approvals Fan motor conforms to ANSI/UL STD 705 Fan motor certified to CSA STD C22.2 NO 113 Environment Indoor only Cartridge Reservoir - 1250ml Disposable/Recyclable Patented Prolitec Inc. Multiple patents pending...
Need help?
Do you have a question about the Air/Q 1100-Avian and is the answer not in the manual?
Questions and answers