Technical data

Taurus 401 Basic FKW

Technical data
8
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
Taurus 401 Basic FKW
Setting range for welding current/voltage:
MMA
MIG/MAG
Duty cycle at 40 °C
100%
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (safety fuse, slow-blow)
Mains connection lead
Maximum connected load
MIG/MAG
MMA
Recommended generator rating
cos
Insulation class/protection classification
Ambient temperature*
Machine/torch cooling
Cooling capacity at 1 l/min
Max. flow rate
Max. coolant outlet pressure
Max. tank capacity
Welding lead
Dimensions L x W x H in mm
Weight
Wire feed speed
Standard roller installation
Drive type
Welding torch connection
EMC class
Constructed to standards
Ambient temperature depends on coolant!
*
Observe the coolant temperature range for the welding torch cooling!
64
NOTE
5 A/20.2 V to 400 A/36.0 V
5 A/14.3 V to 400 A/34.0 V
400 A
10 min. (60% DC
6 min. welding, 4 min. pause)
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 32 A
H07RN-F4G6
17.5 kVA
18.5 kVA
25 kVA
H/IP 23
-25 °C to +40 °C
Fan/gas or water
1500 W
5 l/min
3.5 bar
70 mm²
1100 x 455 x 950
120 kg
0.5 m/min to 24 m/min
1.0 mm + 1.2 mm (for steel wire)
4-roller (37 mm)
Euro torch connector
IEC 60974-1, -2, -5, -10 /
NOTE
79 V
0.99
12 l
A
/
099-005230-EW501
02.04.2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Taurus 401 Basic FKW and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Taurus 501 basic fkw

Table of Contents