8.2
Taurus 501 Basic FKW
Setting range for welding current
Setting range for welding voltage
Duty cycle
60%
65%
100%
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (safety fuse, slow-blow)
Mains connection lead
Maximum connected load
Max. connected load
Recommended generator rating
Cos
Insulation class/protection
classification
Ambient temperature*
Machine/torch cooling
Cooling capacity at 1 l/min
Max. flow rate
Max. coolant outlet pressure
Max. tank capacity
Workpiece lead
Dimensions L x W x H in mm
Weight
Wire feed speed
Standard roller installation
Drive type
Welding torch connection
EMC class
Constructed to standards
Ambient temperature depends on coolant!
*
Observe the coolant temperature range for the welding torch cooling!
099-005230-EW501
02.04.2014
MIG/MAG
5 A–500 A
14.3 V–39.0 V
40 °C
25 °C
500 A
-
-
500 A
430 A
460 A
10 min. (60% DC
6 min. welding, 4 min. pause)
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 32 A
H07RN-F4G6
24.9 kVA
34.6 kVA
H/IP 23
-25 °C to +40 °C
Fan/gas or water
1500 W
5 l/min
3.5 bar
95 mm²
1100 x 455 x 950
124 kg
0.5 m/min. to 24 m/min.
1.0 mm + 1.2 mm (for steel wire)
4-roller (37 mm)
Euro torch connector
IEC 60974-1, -2, -5, -10 /
NOTE
Technical data
Taurus 501 Basic FKW
MMA
20.2 V–40.0 V
40 °C
25 °C
500 A
-
500 A
430 A
460 A
79 V
25.6 kVA
0.99
12 l
A
/
-
65