Installing The Insert Frame & Levelling - HAMPTON BAY greenfire gci60 Technical Manual

Cast iron pellet insert
Hide thumbs Also See for greenfire gci60:
Table of Contents

Advertisement

NOTE: Installer must attach the metal "fireplace altered" tag using screws or nails to the fireplace, in
a location readily visible should the fireplace insert be removed, if the fireplace has been modified to
accomodate the GCI60.
i
i
nStalling the
nSert
Warning: Careless installation is the major cause of safety hazards. Check all local building and safety
codes before installation of unit.
1. Mount Surround Panel to Insert Frame.
2. Place the Insert Frame into the fireplace cavity.
3. Adjust the four levelling bolts until the frame is level. If the fireplace has an un-level surface which
exceeds the length of the bolts, masonry bricks may be placed under the frame.
4. Once level, position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with
the front of the fireplace.
5. Adjust the top anchor bolts to secure it to the lintel. Ready-rod may be substituted if the bolts are not
long enough.
NOTE: Surround Panel
removed for clarity
Hampton GCI60 Cast Pellet Insert Technical Manual
Installation
f
& l
:
rame
evelling
Levelling Bolts
Figure 4: GCI60 Frame.
Anchor Bolts
9