Exhaust Temperature Sensor failure. Bypass sensor located on Exhaust Blower, if stove now operates
properly, the unit may require cleaning or a new sensor. Contact your local dealer for service.
Check the agitator to make sure it is turning properly
3. The exhaust motor will not function normally.
Check the line fuse to see if it has blown.
Open the access panels; check all connections against the wiring diagram.
Check the Exhaust Blower voltage across the blower motor wires (>=115V on #5 setting and >= 75V
on #1 setting). – Replace the Circuit Board if the Voltage reading is less than 75 V. with a line voltage
of >115 V AC.
Clean all exhaust passages and venting.
Check and, if necessary, replace capacitor.
4. Light # 2 on heat output bar flashing (indicates loss of vacuum) check the following:
Make sure the firebox door is latched and sealed
Make sure the ash pan is closed and sealed
Make sure unit and venting is clear of fly ash
Check the vacuum switch
Check all wires and connections
Check hose from vacuum switch to hose barb
Check hose barb that connects hose to back of unit
Check combustion blower fuse
Confirm combustion blower voltage to determine that it is working properly
5. Light # 3 on Heat output bar flashing (The Exhaust Temp. Switch contacts have opened.)
Stove ran out of fuel - check fuel level in the hopper.
See sections #2 - Stove will not operate when hot, #3 - The Exhaust motor will not function normally,
and #5 - Unit is on but auger does not turn at all for more suggestions.
Severe negative pressure in area where unit is installed - Check the operation by opening a window,
does this solve the problem? If it does, install fresh air intake to unit or room. Venting system may
require vertical section to move termination into a low pressure zone.
To reset Circuit Board after a trouble code - push the ON/OFF button.
6. Unit is on but auger motor does not turn at all.
Check the line fuse to see if it has blown.
Check the Door and Ash Pan door - THEY MUST BE CLOSED TIGHT.
If the Auger gear box does not turn but the motor's armature does try to spin, then the auger is
jammed. Try to break apart jam by poking at the jam through the drop tube. If this fails then empty
the hopper and remove the Auger Cover **Remember to re-seal the cover after installation**
Auger stopped running. Pinch, break or blockage in Vacuum Hose
- Check hose for pinch points or damage, replace or re-route as
required. Blow out Vacuum Hose and intake pipe.
Damage to wires between Circuit Board and Vacuum Switch and
Auger Motor - Inspect wires and connectors.
Vacuum Switch failure - Bypass the vacuum switch, if this corrects
the problem check for above problems before replacing the Vacuum
Switch.
Hampton GCI60 Cast Pellet Insert Technical Manual
Troubleshooting
Magnet location on backside of hopper lid
23