CM-080GE/CM-080GE-RA / CB-080GE/CB-080GE-RA
11.4. Input and Output settings
11.4.1 Interfacing with external devices
For interfacing with external devices, the relationship between Line in/out (Digital I/O) and
the external terminal is fixed. Please refer to 6.1. GPIO (Inputs and outputs).
In the camera control tool, it is displayed as Line 1 –TTL Out1.
11.4.2 Setting of input and output
11.4.2.1 How to assign the signal to Line
This function decides which signal is assigned to Digital I/O (Line 1 to Line 8).
The following is the example to set Line5 – Opt In 1. In this case, the line source is the signal
connected to Opt In 1. The line format is automatically set to Opto Coupled.
The following is the example to set the output signal. It selects the output signal from Line3 –
Optical Out 1 from Line source. In the following example, Exposure Active signal is
output. As the line format, TTL is automatically selected.
- 54 -