HWS-1103H-E, 1403H-E
Fan motor output (Lower)
CN300(White)
Case thermostat connector
CN609(Blue)
Power circuit protection
fuse
F100(250V,3.15A,
plastic case)
4-way valve connector
CN701(White)
Compressor ON output
connector
CN704(Blue)
Heator output
connector
CN703(Grey)
External input connector
CN610(Yellow)
Special operation switches
SW801
SW804
Display change-over
switches
SW800
SW803
Temperature sensor
connectors
TL CN604(White)
TD CN603(White)
TO CN602(Yellow)
TE CN601(White)
TS CN600(White)
Alive, abnormal display LEDs
D800
804(Yellow)
D805(Green)
PMV connector
CN710(White)
Initialization switch
SW802
Hydro-outdoor communication
signal LEDs
D503 (Green, Outdoor =>Hydro)
D502 (Amber, Hydro => Outdoor)
Fan motor output (Upper)
CN400(White)
4-way valve protection fuse
F700(250V,3.15A
plastic case)
Connecting cable connector
CN04(White)
Connecting cable protection fuse
F03(250V,10A)
34
Compressor output terminals
CN202
CN201
CN200
Power supply connection
lead wires
P01(Red)
P02(White)
P03(Black)
Power supply protection fuses
F01
(250V,25A)
Electrolytic capacitors
Earth lead wire
P09(Black)