Toshiba HWS-803XWHM3-E Service Manual page 192

Hide thumbs Also See for HWS-803XWHM3-E:
Table of Contents

Advertisement

No.
Part name
11
PMV coil
12
Fan guard
Procedure
1. Detachment
1) Carry out work of item 1 of 1).
2) Turn the coil while pulling upward and then
remove the coil from the PMV main unit.
2. Attachment
1) Surely match the positioning projection of the coil
with the concave part of PMV main unit and then
fix it.
1. Detachment
1) Carry out works of item 1 of 1) and 1 of 2).
REQUIREMENT
To prevent scratch on the product, carry out the work
on cardboard, cloth, etc.
2) Remove the discharge port cabinet and then put
on it so that the fan guard side directs downward.
3) Remove the hooking claws (8 positions) of the fan
guard.
2. Attachment
1) Push the hooking claws (8 positions) with hands
from the front side to fix the claws.
REQUIREMENT
Check that all the hooking claws are fixed at the
specified positions.
Positioning projection
Fan guard
191
Remarks
Concave part
PMV main unit
PMV coil
Bell mouth
Discharge
port cabinet
Hooking claw

Hide quick links: