Toshiba HWS-803XWHM3-E Service Manual page 18

Hide thumbs Also See for HWS-803XWHM3-E:
Table of Contents

Advertisement

Unit name
Hydro unit
Outdoor unit
Heating capacity *1 (kW)
Cooling capacity *2 (kW)
Variable range of compressor frequency
Power source
Operation mode
Electric characteristic *1 *2
Hydro unit
Outdoor unit
Total
Operating noise *1 *2 *4
Hydro unit (dB(A))
Outdoor unit (dB(A))
Coefficient of performance *1 *2
Hydro unit
Outer dimension
Net weight (kg)
Color
Remote controller
Outer dimension *3
Circulating pump
Heat exchanger
Outdoor unit
Outer dimension
Net weight (kg)
Color
Compressor
Fan motor
Refrigerant piping
Connection method
Hydro unit
Outdoor unit
Maximum length (m)
Maximum chargeless length (m)
Maximum height difference (m)
Minimum length (m)
Refrigerant
Refrigerant name
Charge amount (kg)
Water piping
Pipe diameter
Maximum length (m)
Maximum height difference (m)
Maximum working water pressure (kPa)
Operating temperature range
Hydro unit (°C)
Outdoor unit (°C)
Operating humidity range
Hydro unit (%)
Outdoor unit (%)
Wiring connection
Power wiring
Connecting line
*1 Heating performance measurement conditions: outside air temperature 7 °C, water supply temperature 30 °C, outlet temperature 35 °C, refrigerant piping length 7.5 m (no height
difference).
*2 Cooling performance measurement conditions: outside air temperature 35 °C, water supply temperature 12 °C, outlet temperature 7 °C, refrigerant piping length 7.5 m (no height
difference).
*3 • The remote controller should be shipped with the hydro unit.
• Use two 1.5-meter wires to connect the hydro unit with the remote controller.
*4 The outdoor unit operating noise is measured at the point of 1m away from the unit back surface centre and 1m high from the ground. The hydro unit operating noise is measured at the
point of 1m away from the unit front surface centre.
The value of the operating noise varies depending on room structure where the unit is installed.
*5 Do not leave the hydro unit at 5 °C or below.
*6 Check the water piping for leakage under the maximum operating pressure.
Current (A)
Power (kW)
Power factor (%)
Current (A)
Power (kW)
Power factor (%)
Starting current (A)
Height (mm)
Width (mm)
Depth (mm)
Height (mm)
Width (mm)
Depth (mm)
Motor output (W)
Flow rate (L/min)
Type
Height (mm)
Width (mm)
Depth (mm)
Motor output (W)
Type
Model
3
Standard air capacity (m
/min)
Motor output (W)
Liquid
Gas
Liquid
Gas
17
HWS-1403XWHM3-E, 1403XWHT6-E, 1403XWHD6-E, 1403XWHT9-E
HWS-1103H8(R)-E
HWS-1403H8(R)-E
11.2
14.0
10.0
11.0
10 - 60Hz
10 - 60 Hz
3 phase 50Hz 380 - 400V
Heating
Cooling
Heating
0.63
0.61
0.67
0.135
0.130
0.145
93.2
92.7
94.0
4.03
5.65
5.23
2.255
3.39
3.065
81.1
87.0
84.9
4.66
6.26
6.06
29
29
29
49
50
51
4.69
2.84
4.36
925
525
355
54
Silky shade (Munsell 1Y8.5/0.5)
120
120
16
190 (MAX)
32.1
28.9
40.1
Non-self-suction centrifugal pump
Plate-type heat exchange
1340
900
320
93
Silky shade (Munsell 1Y8.5/0.5)
2500
Twin rotary type with DC-inverter variable speed control
DA422A3F-27M
103.0
100 × 2
Flare connection
Ø9.52
Ø15.9
Ø9.52
Ø15.9
30
30
±30
5
R410A
2.7
R1 1/4
None (Need the flow rate 17.5 /min or more)
±7
300
5-32
-20-43
15-85
15-100
5 wires: including ground line (Outdoor unit)
4 wires: including ground line
HWS-1603H8(R)-E
16.0
13.0
10 - 70 Hz
Cooling
Heating
Cooling
0.63
0.69
0.66
0.135
0.150
0.140
93.2
94.5
92.3
6.50
5.95
7.50
3.945
3.570
4.660
88.0
87.0
90.0
7.13
4.26
8.16
29
29
29
51
52
52
2.70
4.30
2.71
31.5
45.8
37.3

Hide quick links:

Advertisement

Table of Contents
loading