3.3.5 INPUT VOLTAGE CONFIGURATION, MODEL 3120-ASX ( cont. )
1. SOME DETAIL OMITTED FOR CLARITY

FIGURE 3.3.5 MODEL 3120-ASX INPUT VOLTAGE CONFIGURATION

INPUT
VOLTAGE
FROM HARNESS
FORM
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
208 VAC DELTA
(ØC) W IRE TO T1-C1
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
220 VAC DELTA
(ØC) W IRE TO T1-C1
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
230 VAC DELTA
(ØC) W IRE TO T1-C1
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
240 VAC DELTA
(ØC) W IRE TO T1-C1
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
220 / 380 VAC
(ØC) W IRE TO T1-C1
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
230 / 400 VAC
(ØC) W IRE TO T1-C1
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
240 / 416 VAC
(ØC) W IRE TO T1-C1
(ØA) W IRE TO T1-A1
(ØB) W IRE TO T1-B1
277 / 480 VAC
(ØC) W IRE TO T1-C1
54
JUMPERS XFMR TO XFMR
JUMPER T1-A1 TO T1-C2
JUMPER T1-B1 TO T1-A2
JUMPER T1-C1 TO T1-B2
JUMPER T1-A1 TO T1-C3
JUMPER T1-B1 TO T1-A3
JUMPER T1-C1 TO T1-B3
JUMPER T1-A1 TO T1-C4
JUMPER T1-B1 TO T1-A4
JUMPER T1-C1 TO T1-B4
JUMPER T1-A1 TO T1-C5
JUMPER T1-B1 TO T1-A5
JUMPER T1-C1 TO T1-B5
JUMPER T1-A3 TO T1-C3
JUMPER T1-B3 TO T1-A3
JUMPER T1-C3 TO T1-B3
JUMPER T1-A4 TO T1-C4
JUMPER T1-B4 TO T1-A4
JUMPER T1-C4 TO T1-B4
JUMPER T1-A5 TO T1-C5
JUMPER T1-B5 TO T1-A5
JUMPER T1-C5 TO T1-B5
JUMPER T1-A6 TO T1-C6
JUMPER T1-B6 TO T1-A6
JUMPER T1-C6 TO T1-B6
BOTTOM VIEW
(BOTTOM COVER CUT AW AY)