2.1.2 OUTPUT POWER

OUTPUT VOLTAGE RANGE
DIRECT-COUPLED
The standard output voltage ranges of the ASX-Series are: 0-132 VAC
115-ASX, 160-ASX, 315-ASX, and 360-ASX; 0-135 VAC
and 3120-ASX; and 0-150 VAC
direct-coupled mode. These voltages are stated for nominal input voltage applied.
TRANSFORMER-COUPLED
The output voltage range of the ASX-Series Power Source varies when operated in the
transformer-coupled mode. Maximum output voltage is determined by the transformer turns
ratio. See list below for maximum output voltage vs. turns ratio.
TURNS RATIO
1.5:1
2.0:1
2.5:1
OUTPUT CURRENT
FULL-RATED CURRENT
The full-rated output current the ASX-Series Power Source is listed below by model number.
Refer to the derating charts of Figures 2.1.2(A-H) for maximum output current at a specific output
form, voltage, or power factor. Output current ratings are scaled appropriately when using
transformer-coupled outputs. Note that the 315-ASX has reduced ratings when the output
magnetics option is installed (the "T" added to the model number designates the output
magnetics option).
magnetics option installed.
MODEL
115-ASX
120-ASX
140-ASX
160-ASX
315-ASX
315-ASXT
(with output magnetics option)
320-ASX
345-ASX
360-ASX
3120-ASX
OVERLOAD OPERATION
The ASX-Series Power Source will deliver up to 125% of rated RMS output current at 25°C
ambient room temperature, nominal through 10% high input line voltage, and at a power factor
of 0.8. Elevated ambient temperatures, low input line voltage, or power factors between 0.8 and
1.0 will increase the internal dissipation of the power source and can cause overload shutdown
due to over-temperature conditions. Length of time to reach over-temperature varies with the
models and the above parameters.
for the Models 120-ASX and 320-ASX, when operated in the
l-n
MAXIMUM OUTPUT VOLTAGE (No Load)
198 VAC
203 VAC
264 VAC
270 VAC
330 VAC
338 VAC
All other models retain their full-rated output current with the output
I
I
out, rms
out, pk
16 A
35 A
20 A
90 A
32 A
90 A
48 A
120 A
12 A
69 A
9 A
69 A
20 A
69 A
36 A
100 A
48 A
120 A
96 A
300 A
for the Models 140-ASX, 345-ASX,
l-n
Models 115-ASX, 160-ASX, 315-ASX, and 360-ASX
l-n
Models 140-ASX, 345-ASX, and 3120-ASX
l-n
Models 115-ASX, 160-ASX, 315-ASX, and 360-ASX
l-n
Models 140-ASX, 345-ASX, and 3120-ASX
l-n
Models 115-ASX, 160-ASX, 315-ASX, and 360-ASX
l-n
Models 140-ASX, 345-ASX, and 3120-ASX
l-n
I
I
out, rms
out, pk
N/A
N/A
14 A
45 A
16 A
45 A
16 A
45 A
6 A
23 A
6 A
23 A
12 A
23 A
12 A
40 A
16 A
45 A
48 A
150 A
12
for the Models
l-n
I
I
out, rms
out, pk
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4 A
23 A
3 A
23 A
7 A
23 A
16 A
40 A
16 A
45 A
32 A
100 A