2.1.1 INPUT POWER REQUIREMENTS (cont.)
INPUT VOLTAGE
The Model 160-ASX accepts one of the following three phase input voltages:
1)
2)
3)
4)
5)
6)
(cost option)
7)
INPUT CURRENT
The input current required by the Model 160-ASX at full rated load is stated below.
Recommended input service is also stated.
1)
208 VAC Δ
2)
220 VAC Δ
3)
240 VAC Δ
4)
220/380 VAC
5)
230/400 VAC
6)
240/416 VAC
7)
277/480 VAC
INPUT VOLTAGE
The Model 315-ASX accepts one of the following single phase input voltages:
1)
2)
3)
4)
5)
6)
7)
8)
INPUT CURRENT
The input current required by the Model 315-ASX at full rated load is stated below.
Recommended input service is also stated.
1)
2)
3)
4)
5)
6)
7)
8)
MODEL 160-ASX
208 VAC Δ ±10%, 47-63 Hz
220 VAC Δ ±10%, 47-63 Hz
240 VAC Δ ±10%, 47-63 Hz
220/380 VAC ±10%, 47-63 Hz
230/400 VAC ±10%, 47-63 Hz
240/416 VAC ±10%, 47-63 Hz
277/480 VAC ±10%, 47-63 Hz
V
INPUT CURRENT
in
20 A
18 A
16 A
11 A
10 A
10 A
8 A
MODEL 315-ASX
100 VAC ±10%, 47-63 Hz
110 VAC ±10%, 47-63 Hz
120 VAC ±10%, 47-63 Hz
200 VAC ±10%, 47-63 Hz
208 VAC ±10%, 47-63 Hz
220 VAC ±10%, 47-63 Hz
230 VAC ±10%, 47-63 Hz
240 VAC ±10%, 47-63 Hz
V
INPUT CURRENT
in
100 VAC
22 A
110 VAC
20 A
120 VAC
18 A
200 VAC
11 A
208 VAC
10 A
220 VAC
10 A
230 VAC
9 A
240 VAC
9 A
SECTION 2
SERVICE RECOMMENDED
rms
rms
rms
rms
rms
rms
rms
SERVICE RECOMMENDED
rms
rms
rms
rms
rms
rms
rms
rms
9
SPECIFICATIONS
30 A
30 A
25 A
15 A
15 A
15 A
15 A
25 A
25 A
25 A
15 A
15 A
15 A
15 A
15 A