Auto Trickle
This feature is used to prevent a host computer from "timing out" because the
parallel interface is "busy" for too long.
Enable (factory default). When the printer's buffers are almost full, the
printer begins to trickle data in from the host (at the rate set in the Trickle
Time menu) until the buffers start to empty out.
Disable. The Auto Trickle feature is not used.
Trickle Time
When the printer is printing data from a host and a second print job is received
by the printer from a different host, Trickle Time prevents the second host
from timing out while it is waiting for its data to be printed. In order to support
this feature, the port has to be able to accept data from the host and store it
for future use.
For example, if the printer is printing a job from the serial port, and then
receives a second print job from the parallel port, the data from the parallel
port will "trickle" bit by bit into the printer buffer to prevent a timeout error from
being sent back to the host connected to the parallel port.
The selected value is the time that the printer waits before getting the next
byte of data from the host. The Trickle Time value should be less than the
host time out value, but not too much shorter or else the printer fills up its
buffer too fast. This function is not applicable for C/T hotport.
The options are 1/4, 1/2, 1, 2, 4, 8, and 16 seconds and Off.
The factory default is 1/4 second.
Timeout
This is the value used by the printer to time out from the current port and
check the other selected port types for data to print. When the printer has not
received data from the host after a certain period of time, it needs to time out
in order to service the other ports.
The range is 1-60 seconds, and the factory default is 10 seconds.
Report Status
Disable (factory default). When a fault occurs on the printer, only the
active port reports the fault to the host.
Enable. The port will report any fault even when it is not the current active
port.
Switch Out On
Data Timeout (factory default). Allows Autoswitching when no data has
been received for the selected Time Out period.
Session Close. Allows Autoswitching only when the Network Socket is
closed. If the Ethernet Adapter is not installed the Network Socket is
always reported as closed and this menu option is ignored.
PARALLEL PORT Submenus
243