Ribbon Width
When Same As Paper is selected, the printer automatically adjusts the ribbon
operating parameters to match the installed media width. In those cases
where the media width is less than the installed ribbon width, the Set In Menu
option should be selected. After selection, the ribbon width is set to the proper
value by pressing the ↓ key and choosing the actual ribbon width using the +
and − keys. The chosen width is then selected by pressing the ↵ key.
The factory default is Same As Paper.
Display Ribbon
When enabled and the printer online, 1 to 4 asterisks will display on the LCD
indicating the approximate amount of ribbon remaining on the supply spindle:
Online Rbn
**** =
*** =
** =
* =
The options are Enable (the factory default) and Disable.
Ribbon Low
When enabled and the amount of ribbon remaining on the supply spindle is
approximately 75 to 50 meters or less, the Online status indicator flashes and
"Ribbon Low" displays on the second line of the LCD. A Ribbon Low warning
message will not prevent printing.
The options are Disable (the factory default) and Enable.
NOTE: The Display Ribbon option must be set to Enable for the warning to
display.
Rbn Takeup Full
This enables or disables a fault message to display for a Ribbon Takeup Full
condition.
The options are Enable (the factory default) and Disable.
Units
This item selects either millimeters or inches as the unit of measure.
The options are In Inches (the factory default) and In Millimeters.
MEDIA CONTROL Submenus
470 to 625m
314 to 469m
157 tp 313m
1 to 156m