Modules within a Controller Canister
In accordance with international transportation regulations, the BBU
module is only charged to between 35% and 45% of its total capacity
when shipped. Therefore, when powering on the system for the first
time, the BBU will begin to charge its batteries to its full capacity. It
normally requires approximately twelve (12) hours for the battery to
be fully charged. If the battery is not fully charged after twelve (12)
hours, there may be a problem with the BBU module. You may re-
install the battery; if the battery still shows problems with charging,
contact your system vendor for a replacement. While the battery is
being charged, the LED on the BBU will start flashing.
You can check the battery's charge level using a terminal console
with firmware's embedded utility.