Low-Level Water Error; Button Error - Samsung DMT800 SERIES Service Manual

Hide thumbs Also See for DMT800 SERIES:
Table of Contents

Advertisement

Error type
Error mode
9E
[Or]

Low-level water error

'Normal' +
'Heavy' + 'Smart
Auto' LED
bE
[Or]

Button error

'Normal' +
'Delicate' LED
4-9
Checking Method
1. Check the connections for the Water-level sensor
connectors.
- Faulty: Replace the Assy case sensor, Remove
foreign material from the floater
- Normal: Replace the Main PBA assy.
Check whether there is condensation on the Main PBA
connector (CN102)
Normal: No condensation
Corrective actions
- Reconnect the Water-level sensor connector.
- Faulty: Replace the Assy case sensor, Remove foreign material from the
floater
- Normal: Replace the Main PBA assy.
- Faulty: Remove any condensation and moisture.
- Normal: Replace the Control Panel assy.