Samsung DMT800 SERIES Service Manual page 39

Hide thumbs Also See for DMT800 SERIES:
Table of Contents

Advertisement

4. Troubleshooting
Mode
Display
Related Parts
'Normal' +
Drain Pump
No.7
'Smart Auto'
Water-level sensor
LED
Inlet Valve
'Normal' +
Circulation Motor
'Delicate' +
No.8
Dry Fan Motor
'Smart Auto'
Drain Pump
LED
Heater
4-6
Symptoms
Drain pump will drain until low level sensor is detected.
Drain Error
If Low level sensor is not detected after 60 seconds, Drain Error ('Delicate' LED) will blink.
Operate each operating part when the key is pressed. (See the below)
When the 'Smart Auto' Key is pressed Water supply is On('Smart Auto' LED On) and pressed again it is Off
('Smart Auto' LED Off)
When 'Heavy' Key is pressed each time, it works the Circulation Motor-1 is On ('Heavy' LED On) -> Off
('Heavy' LED Off) -> Circulation Motor-2 is On ('Heavy' LED On) -> Off ('Heavy' LED Off) -> Dry Fan Motor
is On ('Heavy' LED On) -> Off ('Heavy' LED Off), Drain Pump is On ('Heavy' LED On) -> Off ('Heavy' LED
Off).
When 'Delicate' Key is pressed, it woks Heater On ('Delicate' LED On during 2 seconds) and Off
automatically.
When a different key is pressed during individual operation of the operating part, present operating part is
stopped and the applicable operation for the pressed key will start.
Note