3. Disassembly and Reassembly
Part
Condensing dry
system

Assy Case Vent

&
Assy Dry Duct
&
Assy Duct
Condenser
Assy Case Vent
Reassembly is in the reverse order of the removal.
3-8
Photo
Description
5. Remove the Assy case vent by rotating it
counterclockwise.
6. Remove the Assy dry duct from the Assy duct
condenser.
These parts are fixing by four(4) hooks. To
disassemble, hooks are broke down in the Assy dry
duct.
Caution
Only when dry motor is not working, disassemble it.
After remove it, you should use new Assy dry duct
part to reassemble.
7. Pull out Assy dry duct.
1. Remove the Assy case vent.
2. Release two screws.
3. Pull the thermal actuator firmly to remove it from the
housing and to release it from the gasket vent.