4. Troubleshooting
Mode
Display
Related Parts
Inlet valve
No.8
L
Overflow Sensor
Drain Pump
No.9
S
Water-level sensor
No.10
FL
Half Load Motor
Inlet Valve
Circulation Motor
Dry Fan Motor
No.11
Temperature
Drain Pump
Heater
Half Load Motor
4-4
Symptoms
Water is supplied until Over-level water error (oE) is blinked.
Over level water Error
If Over-level water error (oE) occurs, overflow sensor is OK.
Drain pump will drain until low level sensor is detected.
Drain Error
If Low level sensor is not detected after 60 seconds, Drain Error (5E) will blink.
Buzzer sound is generated when the Half Load Motor is initialized to full load location,
Half load function Error
and the 'FL' will blink.
Operate each operating part when the key is pressed. (See the below)
When the 'Smart Auto' Key is pressed Water supply is On('Smart Auto' LED On) and pressed again it is Off
('Smart Auto' LED Off)
When 'Heavy' Key is pressed each time, it works the Circulation Motor-1 is On ('Heavy' LED On) -> Off
('Heavy' LED Off) -> Circulation Motor-2 is On ('Heavy' LED On) -> Off ('Heavy' LED Off) -> Dry Fan Motor
is On ('Heavy' LED On) -> Off ('Heavy' LED Off), Drain Pump is On ('Heavy' LED On) -> Off ('Heavy' LED
Off).
When 'Delicate' Key is pressed, it woks Heater On ('Delicate' LED On during 2 seconds) and Off
automatically.
When 'Half Load' Key is pressed Half Load Motor is On('Half Load' LED On) and pressed again it is
Off('Half Load' LED Off).
When a different key is pressed during individual operation of the operating part, present operating part is
stopped and the applicable operation for the pressed key will start.
Note