8 Settings

8.18 Constant Q

Overview
With this function you can set a constant reactive power.
This function should be set only when requested by country regulations, authorities or your grid operator.
Accessing the menu
Main menu > Active/Reactive Pwr > Active Power Ctrl > Constant Q
1 0 . S e p 2 0 1 4 1 5 : 3 2
S t a t u s :
O n G r i d
P o w e r :
E - T o d a y :
I n v e r t e r I n f o .
G e n e r a l S e t t i n g s
I n s t a l l S e t t i n g s
A c t i v e / R e a c t i v e P w r
F R T
W a r n i n g :
A d j . w o u l d e f f e c t
e n e r g y p r o d u c t i o n
P a s s w o r d :
* * * *
A c t i v e P o w e r C t r l
R e a c t i v e P o w e r C t r l
C o n s t a n t c o s p h i
C o s p h i ( P )
C o n s t a n t Q
Q ( V )
94
Do not change this setting without prior
consultation with Delta Solar Support.
1.
When the default information is displayed, press any button to open the main menu. Oth-
erwise, repeatedly press the button
0 W
0 k W h
2.
Use the buttons
To confirm your selection, press the button
3.
The menu is protected by password 5555. Use the buttons
To confirm a digit, press the button
4.
Use the buttons
displayed behind the menu entry.
5.
Use the buttons
behind the menu entry.
until the main menu is displayed.
ESC
and
to select Active/Reactive Pwr.
.
ENT
.
ENT
and
to select Reactive Power Ctrl. The current setting is
and
to select Constant Q. The current setting is displayed
Installation and Operation Manual for RPI M6A M8A M10A inverters V1.0 2016-02-03