10.6 REPLACING THE "AIR" SEALING RING

NOTICE
Shaping air and atomizer air not separate!
Poor spray pattern.
Spray jet cannot be adjusted.
Handle the sealing ring (14) with care.
1. Relieve the pressure of the spray gun and device in
accordance with Chapter 7.3.
2. Decommission and clean in accordance with
Chapter 8.1.2.
3. Secure the spray gun with the trigger locking
device.
4. Unscrew the union nut with nozzle guard (33).
5. Remove the air cap (36) together with the nozzle
(13).
6. Remove the defective sealing ring (14) with the help
of pipe tongs or with a large screwdriver.
Assembly:
7. Plug the new sealing ring (14) onto the air cap (36).
8. Place air cap in body of gun together with sealing
ring (14).
9. Attach the union nut (33) and screw it in until
the sealing ring snaps into place in the mounting
groove (audible snap).
10. Demount the union nut (33) and air cap (36) and
complete the spray gun in accordance with Chapter
7.4.

10.7 REPLACING THE SPRING CAP

1
3
4
8 Nm; 5.9 lb ft
ORDER NUMBER DOC 394821
2
B_02666
13
36
4
1
14
2
3
B_02270
33
37