Replacing The „Air" Sealing Ring - WAGNER AC 4600 Professional Operating Manual

Aircoat spray guns for fl at - and round jet nozzles
Hide thumbs Also See for AC 4600 Professional:
Table of Contents

Advertisement

EDITION 06/2012
OPERATING MANUAL
6.6
REPLACING THE „AIR" SEALING RING
Forming air and atomizer air not separate!
Poor spray pattern
Spray jet cannot be adjusted
Treat the distributor seal (F) with care.
SIHI_0030_GB
1. Finishing work and cleaning.
2. Relieve spray gun and unit pressure.
3. Secure gun with trigger safety catch.
4. Unscrew the union nut with nozzle guard (33).
5. Remove air cap (36) and nozzle (13).
6. Remove defective sealing ring (14/F) with the help of pipe tongs or with a large
screwdriver.
7. Mounting:
Fit new distributor seal (14/F) to air cap (36).
8. Place air cap in body of gun together with sealing ring (14).
9. Attach union nut (33) and screw in until the sealing ring snaps into place in the
mounting groove (snap hearable).
10. Demount union nut (33) and air cap (36) and complete spray gun according to
paragraph 5.4.3.
PART NO. DOC394871
CAUTION
13
14 (F)
B_02708
36
33
AC 4600 Pro
33