By pressing the [+]and [-]-keys simultaneously, the boiler will return to operating mode.
Following a manual override the boiler will return to normal (auto control) if no keys are
used within a 15 minute period.

6.1.4 Display of values with more than two digits

The display has only two digits available therefore values over this are displayed as
follows :
- negative values will be indicated by a dot behind the last digit e.g. 1) = -10
- values from 00 to 99 will be indicated without any punctuation marks
- values from 100 to 199 will be indicated by a dot between both digits
e.g. )0 = 100, !0 = 110, (9 = 199.
- values from 200 to 299 will be indicated by a dot behind every digit
e.g. )) = for 200, !) = 210, (( = 299.