230 V
59970LGBW7H011a
LTALW7H000023a

2.6 Electrical connection

Connect the boiler to the fused (3 amp) switch spur unit
adjacent to the boiler.
The switch unit must always be accessible.
When the switch spur is on the following components of this
appliance can be live (230 V):
electrical connection gas combination block;
most parts of the control unit;
ignition transformer;
X1, X2, X4, X5, X6 and X7 terminal strip;
230 V supply cable connection.
59970LTGBW7H011

2.6.1 The control unit

The Remeha Avanta 18v has an electronic regulation and con-
trol unit with an integrated ionisation flame detector. The heart
of the boiler control unit is a microprocessor, the 'abc
controls and protects the boiler.
The maximum rated input of the boiler is 130 W. The boiler is
fully pre-wired internally, all external connections can be made
using the terminal strips X5 - X7 - X9 and 230 V input (X2 ter-
minal). See the diagram for the position of the connectors and
fuse (F2) on the control unit.
The most important properties of the control unit are summa-
rized in table 03.
LTALW7H000023
Manufacturer
Supply voltage
Pre-purge time
Post-purge time
Ignition time
Safety time
Anti-cycling time
Fuse value F1 (230 V)
DC fan
table 03
Any loads other than those specified above are only allowed if
an isolating transformer is used.
17
Sit Controls
230 V – 1ph – 50 Hz
3 s
5 s
2.5 s
5 s
3 till 10 min.
2 AT
24 VDC
Control unit characteristics
, which
®'