3. Problem 3:
Port 16/24 does not work.
‰ Solution 3:
— Make sure you have the correct MDI/MDI-X push button
setting for Port 16/24. Use MDI for uplink, MDI-X for a PC.
4. Problem 4:
There is data loss between the switch and one of the connected network
nodes.
‰ Solution 4:
— Make sure that the distance between the switch and the
connected network device is no greater than 100 m (328 ft).
— Make sure you are using Category 5 cable for 100 Mbps
operation.