Digital Electronic Spray Control (Desc) - WAGNER ProSpray 3.39 Operating Manual

Hide thumbs Also See for ProSpray 3.39:
Table of Contents

Advertisement

Available languages

Available languages

4.7

Digital Electronic Spray Control (DESC)

The Digital Electronic Spray Control (DESC) increases the
functionality of the sprayer. It is installed directly below the
pressure control knob on the control panel. It consists of a
display and four function keys. The display shows various menu
screens that allow the user to customize and monitor sprayer
operation using the function keys.
SET MPa
Display
ACTUAL MPa
Function
Keys
The pressure control knob overrides the Digital
i
Electronic Spray Control (DESC) settings.
Anytime the pressure control knob is turned, the
sprayer pressure will change accordingly.
Function Keys
The function keys are numbered 1–4. Each key is labeled with
an additional function as well.
#1/Menu Key
Pressing the #1 key scrolls through the available menu screens
or performs a function described on the active menu screen.
#2/g Key
Pressing the #2 key performs a function described on the active
menu screen or increases a value.
#3/h Key
Pressing the #3 key performs a function described on the active
menu screen or decrease a value.
#4/Select Key
Pressing the #4 key selects the active menu screen or performs
a function described on the active menu screen.
Menu Screens
Several menu screens are available for the user to customize
and monitor sprayer operation. They include Main Screen,
Volume Pumped, Job Volume, Unit Serial #, Timers, Job Timers,
Service Time, Security Code, Prime, and Rapid Clean.
Main Screen
The Main Screen is the default screen
for the control system at sprayer
startup. Pressing the #2 key switches between PSI, Bar and
MPa units of measure. Press the #1 key to scroll through the
remaining menu screens.
For sprayers equipped with an nine-language
i
Digital Electronic Spray Control (DESC):
Pressing the #2 key at the Main Screen switches
between PSI, Bar and MPa units of measure.
Pressing the #3 key at the Main Screen changes
the language of the text on the display. There are
a total of nine languages available. Each time
the #1 key is pressed, a different language will
appear. The languages, in order of appearance,
are: English, Spanish, Dutch, Danish, Swedish,
German, French, Italian, and Portuguese.
ProSpray 3.39
GB
23.0
22.5
SET MPa
23.0
ACTUAL MPa
22.5
31
Volume Pumped Screen
The Volume Pumped screen shows the
total number of gallons or liters sprayed
by the sprayer.
To select the Volume Pumped screen,
press the #4 key.
Job Volume Screen
The Job Volume screen allows the user
to reset a liter counter to track usage on
specific jobs.
To select the Job Volume screen, press
the #4 key.
Unit Serial # Screen
The Unit Serial # screen shows the
sprayers serial number.
To select the Unit Serial # screen, press
the #4 key.
Timers Screen
The Timers screen shows the total time
the sprayer has been turned on as well
as the total time the sprayer has been running (pumping).
To select the Timers screen, press the
#4 key.
Job Timers Screen
The Job Timers screen allows the user
to reset the "ON TIME" and "RUN TIME"
to track time on specific jobs.
To select the Job Timers screen, press
the #4 key. "JOB ON" screen will
appear. Press #3 to reset. Press #1 to
continue to "JOB RUN" screen. Press
#3 to reset. Press #1 to scroll through
the remaining menu screens.
Service Time Screen
The Service Time screen allows the user
to set a service time interval (in hours).
Below the set time, the screens shows the current amount of
hours on the sprayer since the last activation of the service timer.
To select the Service Timer screen, press the #4 key.
To set the service time, press the #2
(up) and/or the #3 (down) keys to the
desired time (run hours will increase/decrease in increments of
25 for each time you press a key).
When the service time interval is set and met by the run hours,
the display will show a "Service Required" screen. The pump
will remain functional. To return to the Main Screen, press the
#1 key. Doing so will reset the "Service @" and "Run Hours"
displayed on the Service Screen back to 0.
Starting operation
VOLUME PUMPED
MENU-1
SELECT-4
GALLONS
X
MENU-1
LITRES-2
LITRES
X
MENU-1
GALLONS-2
JOB VOLUME
MENU-1
SELECT-4
GALLONS
XXXX
MENU-1
RESET-3
UNIT SERIAL #
MENU-1
SELECT-4
SER # XXXXXXXXXX
MENU-1
TIMERS
MENU-1
SELECT-4
ON TIME
XXXX
RUN TIME
XXXX
JOB TIMERS
MENU-1
SELECT-4
JOB ON
X
MENU-1
RESET-3
JOB RUN
X
MENU-1
RESET-3
SERVICE TIME
MENU-1
SELECT-4
SERVICE @
XX
RUN HOURS
XX

Advertisement

Table of Contents
loading

Table of Contents